First Alert SMICO110

First Alert BRK SMICO110

10-Year Battery Combination Smoke & Carbon Monoxide Alarm User Manual

Model: SMICO110 | Brand: First Alert

Perkenalan

This manual provides essential information for the proper installation, operation, and maintenance of your First Alert BRK SMICO110 10-Year Battery Combination Smoke & Carbon Monoxide Alarm. This device is designed to provide reliable 2-in-1 protection against both smoke and carbon monoxide, featuring a sealed 10-year battery that eliminates the need for battery replacements for the life of the alarm. Please read these instructions thoroughly before installation and retain this manual for future reference.

Fitur Utama

  • Precision Detection Technology: Advanced sensing technology complies with new industry standards to reduce nuisance alarms from cooking and provides early warning for home fire emergencies.
  • Baterai Tertutup 10 Tahun: Eliminates battery replacements and low battery chirps for the entire life of the alarm, offering continuous protection.
  • Peringatan Akhir Masa Pakai: Alerts you when the alarm needs to be replaced, typically after 10 years of operation.
  • Perlindungan Ganda: Provides reliable 2-in-1 protection against both smoke and carbon monoxide.
  • Tombol Tes/Diam: Allows for efficient testing to ensure the alarm is functioning correctly and to silence nuisance alarms.

Pengaturan dan Instalasi

The First Alert BRK SMICO110 alarm is designed for easy installation. It can replace existing hardwired alarms using compatible mounting bases or be installed as a new unit. Ensure power is off at the circuit breaker before beginning installation.

Penempatan yang Direkomendasikan

For optimal safety, install combination smoke and carbon monoxide alarms on every level of your home and in every bedroom. Refer to local codes for specific requirements.

Diagram showing recommended placement of smoke and carbon monoxide alarms and fire extinguishers in a house layout.

Image: Recommended placement of alarms throughout a home.

A person installing a smoke alarm on a ceiling, with a graphic indicating installation on every level and in every bedroom.

Image: Visual guide for installing alarms on every level and in every bedroom.

Langkah-langkah Instalasi

  1. Prepare the Mounting Base: If replacing an old alarm, remove the old unit and its mounting base. The BRK SMICO110 often uses a universal mounting base that may be compatible with existing wiring and screw arrangements. If not, install the new mounting base provided.
  2. Kembali view of the First Alert BRK SMICO110 alarm, showing the mounting plate and wiring connections.

    Image: Back of the alarm with mounting plate.

  3. Connect Wiring (if hardwired): Connect the alarm's wiring harness to your home's electrical system. Match black to black, white to white, and orange to orange (or red for interconnect). Ensure all connections are secure.
  4. Aktifkan Baterai: Pull the yellow tab to activate the sealed 10-year battery. You may hear a chirp indicating activation.
  5. Mount the Alarm: Align the alarm with the mounting base and twist clockwise until it locks securely into place.
  6. Depan view of the First Alert BRK SMICO110 alarm, showing the test/silence button and indicator lights.

    Gambar: Depan view dari alarm.

  7. Uji Alarm: Press and hold the Test/Silence button until the alarm sounds. This confirms the unit is functioning correctly.

Petunjuk Pengoperasian

Your First Alert BRK SMICO110 alarm operates continuously once activated. It monitors for both smoke and carbon monoxide.

  • Deteksi Asap: When smoke is detected, the alarm will sound a loud, intermittent horn pattern (three long beeps, pause, three long beeps).
  • Carbon Monoxide Detection: When carbon monoxide is detected, the alarm will sound a distinct four-beep pattern, pause, and repeat.
  • Tombol Tes/Diam: Press this button to test the alarm's functionality or to silence a nuisance alarm (e.g., from cooking smoke). The alarm will temporarily silence for several minutes before resetting.
  • Peringatan Akhir Masa Pakai: After approximately 10 years, the alarm will emit a specific end-of-life signal (e.g., two chirps every 30 seconds) to indicate it needs replacement.

Pemeliharaan

Regular maintenance ensures your alarm functions optimally.

  • Pengujian Mingguan: Test your alarm weekly by pressing and holding the Test/Silence button until the alarm sounds.
  • A person testing a smoke alarm on the ceiling, with text 'Test alarms regularly'.

    Image: Regular testing of the alarm.

  • Pembersihan: Dust and debris can affect alarm performance. Gently vacuum the alarm's cover and vents monthly using a soft brush attachment. Do not paint the alarm.
  • Penggantian: Replace the entire alarm unit at least every 10 years from the date of manufacture, or immediately if the end-of-life warning sounds.
  • A woman holding a smoke alarm, with text 'Replace alarms at least every 10 years'.

    Image: Reminder to replace alarms every 10 years.

Penyelesaian Masalah

MasalahKemungkinan PenyebabLarutan
Alarm sounds intermittently (chirping).Peringatan akhir kehidupan.Replace the alarm unit immediately.
Nuisance alarms (e.g., during cooking).Smoke from cooking or steam.Press the Test/Silence button to temporarily silence the alarm. Ensure proper ventilation in cooking areas. Relocate the alarm if nuisance alarms persist.
Alarm tidak berbunyi selama pengujian.Battery not activated or unit malfunction.Ensure the yellow battery activation tab has been pulled. If the issue persists, the unit may be faulty and require replacement.

Spesifikasi

FiturDetil
MerekPeringatan Pertama
Nomor ModelSMICO110
Sumber DayaBattery Powered (10-Year Sealed Battery)
Jenis AlarmCombination Smoke & Carbon Monoxide
Jenis SensorIonization (for smoke)
Dimensi Produk5.6"Panjang x 5.6"Lebar x 2"T
Daya Tahan Baterai10 tahun
WarnaPutih
PabrikanTempat tinggal

Garansi dan Dukungan

The First Alert BRK SMICO110 alarm comes with a Garansi Produsen Terbatas 10 Tahun. For warranty claims or technical support, please refer to the contact information provided in the packaging or visit the official First Alert webJangan mencoba memperbaiki unit sendiri.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.