Leviton 2610

Leviton 2610 30 Amp 125V Flush Mount Locking Receptacle User Manual

1. Pendahuluan

The Leviton 2610 is an industrial-grade flush mounting locking receptacle designed for reliable electrical connections. This 30 Amp, 125 Volt device ensures secure power delivery in demanding environments, preventing accidental disconnection of power cords. It is built with high-quality materials to provide superior performance and dependability.

Leviton 2610 30 Amp 125V Flush Mount Locking Receptacle

Gambar 1.1: Depan view of the Leviton 2610 30 Amp 125V Flush Mount Locking Receptacle.

2. Informasi Keselamatan

PERINGATAN: Risk of electric shock. Improper installation or use can result in serious injury or death. Always follow these safety guidelines:

3. Fitur Produk

4. Spesifikasi

Nomor Model2610
MerekLeviton
Peringkat listrik30 Amp, 125Volt
Konfigurasi3-Wire, Grounding
Jenis PemasanganSiram gunung
WarnaHitam
BahanPadat
Dimensi Produk1.3"P x 3.5"L
Berat Barang3.68 ons
PabrikanLEVITON MFG CO INC

5. Pengaturan dan Instalasi

Installation of this electrical device should only be performed by a qualified electrician. Adherence to all national and local electrical codes is mandatory.

  1. Putuskan Daya: Before beginning any work, ensure the power supply to the circuit is completely disconnected at the main circuit breaker or fuse box. Use a voltage tester to confirm the circuit is de-energized.
  2. Persiapan Pengkabelan: Strip insulation from the circuit wires (hot, neutral, ground) to the appropriate length as specified by the receptacle's terminals. Ensure only copper conductors are used.
  3. Hubungkan Kabel: Connect the wires to the corresponding terminals on the Leviton 2610 receptacle. Typically, the hot wire connects to the brass terminal, the neutral wire to the silver terminal, and the ground wire to the green terminal. Tighten all terminal screws securely.
  4. Dudukan Stopkontak: Carefully fold the wires into the electrical box and secure the receptacle to the box using the provided mounting screws. Ensure the receptacle is flush with the wall surface.
  5. Pasang Pelat Penutup: Attach a compatible cover plate (sold separately) over the installed receptacle.
  6. Pulihkan Daya: Once installation is complete and all connections are secure, restore power at the circuit breaker and test the receptacle for proper operation.

6. Petunjuk Pengoperasian

To use the Leviton 2610 locking receptacle:

  1. Masukkan Steker: Align the blades of the compatible locking plug with the corresponding slots on the receptacle.
  2. Lock Plug: Insert the plug fully into the receptacle. Once inserted, twist the plug clockwise until it locks securely into place. This locking action prevents accidental disconnections.
  3. Lepaskan Steker: To disconnect, twist the plug counter-clockwise to unlock it, then pull the plug straight out from the receptacle.

7. Pemeliharaan

Regular inspection and basic maintenance can help ensure the longevity and safe operation of your Leviton 2610 receptacle:

8. Penyelesaian masalah

If you encounter issues with your Leviton 2610 receptacle, consider the following:

9. Garansi dan Dukungan

For detailed warranty information, technical support, or to find authorized service centers, please visit the official Leviton website or contact Leviton customer service directly. Keep your purchase receipt as proof of purchase for any warranty claims.

Dokumen Terkait - 2610

Praview Panduan Pemasangan dan Pengujian Stopkontak GFCI Leviton
Panduan lengkap tentang cara memasang dan menguji Leviton SmartLock Pro GFCI Receptacle, termasuk petunjuk pemasangan kabel, tindakan pencegahan keselamatan, dan kiat pemecahan masalah.
Praview Manual Instalasi dan Pengoperasian Stopkontak GFCI Leviton dengan Port USB
Panduan lengkap untuk memasang dan mengoperasikan Stopkontak GFCI Leviton dengan Port USB, termasuk petunjuk pemasangan kabel, peringatan keselamatan, prosedur pengujian, dan informasi garansi.
Praview Panduan Komprehensif tentang Cara Memasang dan Menguji Stopkontak GFCI Pintar Leviton:
Petunjuk langkah demi langkah untuk memasang dan menguji stopkontak Leviton Smart GFCI (model D2GF1, D2GF2). Pelajari tentang fungsi GFCI, pemasangan kabel, pemecahan masalah, dan tindakan pencegahan keselamatan.
Praview Panduan Instalasi dan Pengujian Stopkontak GFCI Leviton SmartlockPro
Panduan lengkap untuk memasang dan menguji stopkontak Ground Fault Circuit Interrupter (GFCI) Leviton SmartlockPro. Mencakup tindakan pencegahan keselamatan, pemasangan kabel, pemecahan masalah, dan fitur produk.
Praview Panduan Pemilihan Sakelar Kelas Komersial & Industri Leviton
Panduan pemilihan komprehensif dari Leviton yang merinci sakelar kelas komersial dan industri, termasuk sakelar toggle, Decora Plus, Lev-lok, antimikroba, dan jenis sakelar khusus dengan detail aplikasi dan diagram pengkabelan.
Praview Leviton EV40P Seri EV 40 AMP Panduan Pemasangan Pengisi Daya Colok
Manual instalasi untuk Leviton EV40P EV Series 40 AMP Pengisi Daya Kendaraan Listrik Plug-In. Termasuk peringatan keselamatan, spesifikasi, langkah-langkah pemasangan, prosedur pengoperasian, penggunaan kartu RFID, pesan kesalahan, perawatan, dan informasi garansi.