This manual provides essential information for the proper installation, operation, and maintenance of your AGS BL520 Brake Line. The AGS BL520 is a high-quality steel brake line designed for automotive braking systems. Please read this manual thoroughly before installation to ensure safety and optimal performance.

Produk Selesaiview

The AGS BL520 is a durable steel brake line, measuring 20 inches in length, designed to withstand the pressures and conditions of an automotive braking system. It features standard fittings for secure connections.

AGS BL520 Brake Line with fittings

Gambar: Close-up view of the AGS BL520 steel brake line, showing the main steel tubing and the two threaded brass-colored fittings at each end. The line appears straight and rigid.

Fitur Utama:

Spesifikasi

AtributDetil
MerekAGS
Nomor ModelBL520
BahanBaja Paduan
WarnaBaja
Dimensi Produk (P x L)20"P x 0.5"L (50.8 cm x 1.27 cm)
Ketebalan Dinding Nominal1.3 mm
Berat Barang2.4 ons (0.068 kg)
UPC077146359163

Pedoman Instalasi

Installation of brake lines should only be performed by qualified personnel with appropriate tools and safety equipment. Improper installation can lead to brake system failure and serious injury.

Alat dan Bahan yang Dibutuhkan:

Langkah-langkah Instalasi:

  1. Keselamatan adalah yang utama: Ensure the vehicle is securely lifted and supported on jack stands. Disconnect the negative terminal of the battery.
  2. Drain Brake Fluid: Place a drain pan under the master cylinder or the lowest point of the brake system. Open the bleeder valves to drain the old brake fluid.
  3. Hapus Baris Lama: Carefully loosen and remove the fittings connecting the old brake line. Be prepared for residual brake fluid to leak.
  4. Periksa Koneksi: Before installing the new line, inspect the mating surfaces for corrosion or damage. Clean as necessary.
  5. Install New Line: Route the new AGS BL520 brake line exactly as the original. Ensure there are no kinks or sharp bends. Hand-tighten the fittings first to avoid cross-threading.
  6. Kencangkan Perlengkapan: Using a flare nut wrench, tighten the fittings to the manufacturer's specified torque. Jangan terlalu kencang.
  7. Refill and Bleed: Refill the master cylinder with new, clean brake fluid. Bleed the entire brake system according to your vehicle's service manual to remove all air.
  8. Periksa Kebocoran: After bleeding, apply firm pressure to the brake pedal and check all new connections for leaks. Repeat this process several times.
  9. Uji Coba: Perform a low-speed test drive in a safe area to confirm proper brake function before normal operation.

Operasi

The AGS BL520 Brake Line is a passive component within your vehicle's hydraulic braking system. Its primary function is to safely transfer hydraulic pressure from the master cylinder to the brake calipers or wheel cylinders, enabling the vehicle to slow down or stop. Once properly installed and the brake system is bled, the brake line operates continuously as part of the braking circuit.

Proper operation relies on a sealed system free from leaks and air. Any compromise to the integrity of the brake line or its connections will directly impact braking performance.

Pemeliharaan

Regular inspection and maintenance are crucial for the longevity and safety of your brake system, including the AGS BL520 Brake Line.

Penyelesaian Masalah

If you experience issues with your braking system after installing or while using the AGS BL520 Brake Line, consider the following common problems and solutions:

Catatan: For any persistent or severe braking issues, consult a certified automotive technician immediately. Do not attempt to drive a vehicle with compromised brakes.

Informasi Garansi

For specific warranty terms and conditions regarding the AGS BL520 Brake Line, please refer to the official AGS manufacturer's warranty documentation provided with your purchase or visit the AGS official website. Warranty coverage typically addresses manufacturing defects and material flaws under normal use conditions.

Dukungan Pelanggan

If you require further assistance, have questions about the AGS BL520 Brake Line, or need technical support, please contact AGS customer service through their official channels. You can typically find contact information on the manufacturer's websitus atau pada kemasan produk.

For general inquiries or to find more products from AGS, you may visit the Toko AGS di Amazon.

Dokumen Terkait - BL520

Praview Lembar Spesifikasi Sensor CO2, Suhu, dan Kelembapan Pemasangan Saluran Digital AGS TP-DS-CO2RHT-BMS
Dokumen ini merinci spesifikasi AGS TP-DS-CO2RHT-BMS, sensor pemasangan saluran digital untuk CO2, suhu, dan kelembapan. Sensor ini dilengkapi teknologi NDIR, kompatibilitas BACnet MS/TP dan Modbus RTU, serta kalibrasi otomatis untuk aplikasi HVAC.
Praview Konfigurasi Umum Ponsel Bluetooth untuk Jaringan VRS dengan TSC2
Panduan lengkap yang merinci langkah-langkah untuk mengonfigurasi ponsel berkemampuan Bluetooth agar berfungsi dengan VRS Networks menggunakan perangkat TSC2. Meliputi pengaturan awal ponsel, pemasangan Bluetooth, pembuatan koneksi jaringan, dan pengujian koneksi internet.
Praview Mini Merlin LPGCO-50 Dual Gas Controller Installation and Operation Manual
Comprehensive installation and operation instructions for the AGS Mini Merlin LPGCO-50 Dual Gas Controller, covering safety, setup, maintenance, and specifications for detecting Carbon Monoxide (CO) and LPG.
Praview Manual Instalasi dan Pengoperasian Sensor Gas Refrigeran VRF Seri Merlin RG
Manual instalasi dan pengoperasian komprehensif untuk Sensor Gas Refrigeran VRF Seri AGS Merlin RG. Mencakup informasi keselamatan penting, prosedur instalasi, pengkabelan, konfigurasi, pengoperasian, kalibrasi, dan spesifikasi teknis.
Praview AGS-GSV Gas Solenoid Valve: Installation and Maintenance Guide
Comprehensive installation and maintenance instructions for the AGS-GSV Gas Solenoid Valve by American Gas Safety. Covers specifications, dimensions, capacity, pressure drop, installation, electrical connections, and coil care.
Praview Detektor Gas Merlin iS: Manual Instalasi, Pengoperasian & Perawatan oleh American Gas Safety
Manual ini memberikan petunjuk terperinci untuk detektor gas American Gas Safety Merlin iS, meliputi instalasi, pengoperasian, perawatan, pemecahan masalah, dan spesifikasi untuk deteksi gas pendingin.