Leviton 21254-HW

Leviton 21254-HW 20A 125V Hospital Grade 4-in-1 Receptacle Instruction Manual

1. Produk Lebihview

The Leviton 21254-HW is a 20 Amp, 125 Volt, Industrial Series Extra Heavy Duty Hospital Grade 4-in-1 Receptacle. Designed for demanding environments, this straight blade, grounding receptacle provides four outlets in a single unit, suitable for applications requiring high-abuse tolerance such as healthcare facilities, manufacturing plants, and schools. It features a durable nylon body and face, a 5-20R configuration, and is approved by UL 498, CSA C22.2, and ISO 9001 standards.

Depan view of the Leviton 21254-HW 4-in-1 receptacle

Gambar 1: Depan view of the Leviton 21254-HW 4-in-1 Receptacle, showing the four outlets and 'HOSPITAL GRADE' marking.

2. Informasi Keselamatan

PERINGATAN: To avoid fire, shock, or death, turn OFF power at the circuit breaker or fuse box and test that power is OFF before wiring. This device must be installed in accordance with all national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.

  • Always disconnect power before working on electrical circuits.
  • Use only copper wire for connections.
  • Pastikan grounding yang tepat untuk mencegah sengatan listrik.
  • Jangan melebihi volume yang ditentukantage dan peringkat arus perangkat saat ini.
  • Keep children away from electrical work.

3. Fitur Produk

  • Konstruksi Tahan Lama: Interlocking thermoplastic nylon cover and body for enhanced resilience.
  • High Performance Contacts: Extra heavy-duty, T-type triple-wipe bronze contacts ensure maximum electrical performance and longevity.
  • Desain Serbaguna: Accommodates up to four Fed Spec size straight or angled plugs simultaneously.
  • Identifikasi yang Jelas: Easy-to-read voltage dan amperage ratings are molded directly onto the face of the receptacle.
  • Sertifikasi: UL 498, CSA C22.2, and ISO 9001 approved, ensuring compliance with safety and quality standards.

4. Pengaturan dan Instalasi

Installation of the Leviton 21254-HW receptacle requires basic electrical knowledge. If you are not comfortable performing electrical work, please consult a licensed electrician.

Alat yang dibutuhkan:

  • Obeng (Phillips dan/atau Flathead)
  • Pengupas Kawat
  • Jil.tage Penguji
  • Pita Listrik (opsional)

Langkah-langkah Instalasi:

  1. Matikan Daya: Locate the circuit breaker or fuse that controls the outlet you are replacing or installing. Turn it OFF. Use a voltage tester to confirm that the power is completely off at the outlet.
  2. Remove Old Receptacle (if applicable): Unscrew the wall plate and then the mounting screws holding the old receptacle in the electrical box. Carefully pull the old receptacle out of the box.
  3. Identifikasi Kabel: You will typically find three types of wires:
    • Black or Red (Hot/Line): Carries power.
    • Putih (Netral): Completes the circuit.
    • Tembaga Hijau atau Tembaga Telanjang (Tanah): Kawat pengaman.
  4. Siapkan Kabel: If necessary, strip approximately 1/2 inch of insulation from the end of each wire.
  5. Connect Wires to New Receptacle:
    • Hubungkan Tembaga Hijau atau Telanjang (Tanah) kabel ke Sekrup Tanah Hijau on the receptacle.
    • Hubungkan Putih (Netral) kabel ke Sekrup Perak terminal.
    • Hubungkan Black or Red (Hot/Line) kabel ke Sekrup Kuningan terminal.

    Ensure all connections are tight and secure. The receptacle is designed for 3-wire connections.

  6. Dudukan Stopkontak: Carefully push the wired receptacle back into the electrical box. Secure it with the mounting screws.
  7. Pasang Pelat Dinding: Attach the decorative wall plate over the receptacle.
  8. Pulihkan Daya: Turn the circuit breaker or fuse back ON.
  9. Tes: Plug a device into each of the four outlets to ensure proper function.
Kembali view of the Leviton 21254-HW receptacle showing wiring terminals

Gambar 2: Kembali view of the Leviton 21254-HW Receptacle, illustrating the screw terminals for wiring connections (Ground, Neutral, Hot).

5. Petunjuk Pengoperasian

The Leviton 21254-HW 4-in-1 Receptacle operates like any standard electrical outlet. Once properly installed and powered, it is ready for use.

  1. Plug In Devices: Insert the plug of your electrical device into any of the four available outlets. The design allows for multiple plugs, including those with larger adapters, to be used simultaneously.
  2. Menghidupkan Perangkat: Turn on your electrical device as usual.

Penting: Do not overload the receptacle or the circuit it is connected to. Ensure the total current draw of all connected devices does not exceed the 20 Amp rating of the receptacle or the circuit breaker.

6. Pemeliharaan

The Leviton 21254-HW receptacle is designed for durability and requires minimal maintenance.

  • Pembersihan: To clean the receptacle, ensure power is OFF at the circuit breaker. Wipe the surface with a soft, damp kain. Jangan gunakan pembersih atau pelarut yang bersifat abrasif.
  • Inspeksi Berkala: Periodically inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, turn off power and replace the receptacle immediately.
  • Kekencangan Sambungan: If you suspect a loose connection, turn off power at the circuit breaker and carefully check the wire terminals for tightness.

7. Penyelesaian masalah

If you encounter issues with your Leviton 21254-HW receptacle, consider the following troubleshooting steps:

No Power at Receptacle:

  • Periksa Pemutus Sirkuit: Verify that the circuit breaker controlling the receptacle is in the ON position. If it has tripped (moved to the OFF or middle position), reset it by pushing it firmly to OFF and then to ON.
  • Uji Outlet Lainnya: Check if other outlets on the same circuit are working. If not, the issue is likely with the circuit breaker or wiring to the circuit.
  • Periksa Kabel: With power OFF at the breaker, carefully remove the wall plate and receptacle. Check that all wires are securely connected to their respective terminals (Hot to Brass, Neutral to Silver, Ground to Green). Ensure no wires are loose or frayed.
  • Kelebihan muatan: Ensure the total load of devices plugged into the receptacle does not exceed 20 Amps. Unplug some devices and retest.

Sambungan Steker Longgar:

  • The Leviton 21254-HW features heavy-duty contacts designed for secure connections. If a plug feels loose, ensure it is fully inserted. If the issue persists with multiple plugs, the receptacle may be worn and require replacement.

Jika langkah-langkah pemecahan masalah tidak menyelesaikan masalah, konsultasikan dengan teknisi listrik yang berkualifikasi.

8. Spesifikasi

Dimensions of the Leviton 21254-HW receptacle

Figure 3: Product dimensions of the Leviton 21254-HW Receptacle.

SpesifikasiDetil
Nomor Model21254-HW
MerekLeviton
Peringkat Saat Ini20 Amp
Jil.tage Peringkat125 Volt
Konfigurasi5-20R
Jumlah kabel3
Jumlah Polandia2
PembumianYa
BahanNylon (Body/Face), Steel (Strap)
WarnaPutih
Dimensi Produk4.7"L x 4.6"W (Face), 12.75 x 5.13 x 8.5 inches (Packaging)
Berat Barang6.4 ons
PersetujuanUL 498, CSA C22.2, ISO 9001

9. Garansi dan Dukungan

For warranty information and technical support regarding your Leviton 21254-HW receptacle, please refer to the official Leviton website or contact Leviton customer service directly. Warranty terms typically cover defects in materials and workmanship under normal use.

Leviton Customer Service: Untuk bantuan, kunjungi Toko Leviton di Amazon atau perusahaan resmi mereka weblokasi.

Dokumen Terkait - 21254-HW

Praview Manual Instalasi dan Pengoperasian Stopkontak GFCI Leviton dengan Port USB
Panduan lengkap untuk memasang dan mengoperasikan Stopkontak GFCI Leviton dengan Port USB, termasuk petunjuk pemasangan kabel, peringatan keselamatan, prosedur pengujian, dan informasi garansi.
Praview Panduan Komprehensif tentang Cara Memasang dan Menguji Stopkontak GFCI Pintar Leviton:
Petunjuk langkah demi langkah untuk memasang dan menguji stopkontak Leviton Smart GFCI (model D2GF1, D2GF2). Pelajari tentang fungsi GFCI, pemasangan kabel, pemecahan masalah, dan tindakan pencegahan keselamatan.
Praview Panduan Instalasi dan Pengujian Stopkontak GFCI Leviton SmartlockPro
Panduan lengkap untuk memasang dan menguji stopkontak Ground Fault Circuit Interrupter (GFCI) Leviton SmartlockPro. Mencakup tindakan pencegahan keselamatan, pemasangan kabel, pemecahan masalah, dan fitur produk.
Praview Panduan Pemasangan dan Pengujian Stopkontak GFCI Leviton
Panduan lengkap tentang cara memasang dan menguji Leviton SmartLock Pro GFCI Receptacle, termasuk petunjuk pemasangan kabel, tindakan pencegahan keselamatan, dan kiat pemecahan masalah.
Praview Panduan Pemilihan Sakelar Kelas Komersial & Industri Leviton
Panduan pemilihan komprehensif dari Leviton yang merinci sakelar kelas komersial dan industri, termasuk sakelar toggle, Decora Plus, Lev-lok, antimikroba, dan jenis sakelar khusus dengan detail aplikasi dan diagram pengkabelan.
Praview Panduan Pemasangan Rel DIN GFCI Leviton GFNT1-DIN/GFNT2-DIN
Panduan lengkap untuk memasang dan menguji Stopkontak GFCI Pemasangan Rel DIN GFNT1-DIN dan GFNT2-DIN Leviton, termasuk petunjuk pemasangan kabel, tindakan pencegahan keselamatan, dan pemecahan masalah.