Leviton 1254-R

Leviton 15 Amp 125 Volt Industrial Grade 4-in-1 Receptacle (Model 1254-R) Instruction Manual

Model: 1254-R

1. Pendahuluan

This manual provides detailed instructions for the safe installation, operation, and maintenance of the Leviton 15 Amp, 125 Volt, Industrial Series Extra Heavy Duty Grade, 4-In-1 Receptacle, Model 1254-R. This device is designed for demanding environments requiring high-abuse tolerance, such as healthcare facilities, manufacturing plants, and educational institutions. It features four outlets in a single-gang footprint, offering increased power access without requiring larger electrical boxes.

2. Informasi Keselamatan

PERINGATAN: To avoid fire, shock, or death, turn off power at the circuit breaker or fuse box and test that power is off before wiring. All wiring must be in accordance with national and local electrical codes. If you are unsure about any part of these instructions, consult a qualified electrician.

3. Isi Paket

The package for the Leviton 1254-R 4-in-1 Receptacle typically includes:

4. Spesifikasi

FiturDetil
Nomor Model1254-R
Ampmarah15 Amp
Jil.tage125 Volt
NilaiIndustrial Series Extra Heavy Duty Grade
Jenis Wadah4-In-1, Straight Blade, Grounding
WarnaMerah
BahanThermoplastic Nylon (Cover and Body)
Opsi PengkabelanBack and Side Wiring
KontakExtra Heavy-Duty, T-type triple-wipe bronze
UkuranSekitar 8 x 8 x 8 inci (Dimensi Produk)
BeratSekitar 6.4 ons

5. Instalasi

Follow these steps for proper installation of your Leviton 4-in-1 Receptacle. If you are not familiar with electrical wiring, consult a qualified electrician.

  1. Matikan Daya: Locate the circuit breaker or fuse that controls the outlet where you intend to install the receptacle. Turn it OFF. Verify that the power is off using a voltage penguji.
  2. Remove Old Receptacle (if applicable): Unscrew the wall plate and then the mounting screws holding the existing receptacle in the electrical box. Carefully pull the old receptacle out of the box.
  3. Lepaskan Kabel: Disconnect the wires from the old receptacle. Note which wire was connected to which terminal (hot, neutral, ground).
  4. Siapkan Kabel: Strip approximately 1/2 inch of insulation from the ends of the wires if necessary. Ensure the wire ends are clean and straight.
  5. Connect Wires to New Receptacle:
    • Hubungkan HOT (Black or Red) kabel ke Kuningan sekrup terminal.
    • Hubungkan NETRAL (Putih) kabel ke Perak sekrup terminal.
    • Hubungkan GROUND (Green or Bare Copper) kabel ke Hijau sekrup pentanahan.

    This receptacle supports both back-wiring (inserting wires into holes on the back and tightening screws) and side-wiring (wrapping wires around terminal screws). Ensure connections are tight and no bare wire is exposed outside the terminals.

    Leviton 1254-R 4-in-1 Receptacle, Red

    Gambar 5.1: Depan view of the Leviton 1254-R 4-in-1 Receptacle in Red. This image shows the four outlets and the robust construction.

    Close-up of receptacle wiring terminals

    Gambar 5.2: Close-up view of a Leviton receptacle's wiring terminals, illustrating the side-wiring option and the grounding screw.

  6. Dudukan Stopkontak: Carefully push the wired receptacle back into the electrical box. Secure it with the provided mounting screws.
  7. Pasang Pelat Dinding: Attach the wall plate over the receptacle.
  8. Pulihkan Daya: Turn the circuit breaker or fuse back ON.
  9. Tes: Plug a device into each of the four outlets to ensure proper function.

The 1254-R features an interlocking thermoplastic nylon cover and body for enhanced durability and a nickel-plated brass strap with integral ground contacts for reliable grounding. The permanent "Green Dot" marking on the face indicates its hospital/industrial grade compliance.

Close-up of receptacle with green dot marking

Image 5.3: Detail showing the "Green Dot" marking, signifying the industrial/hospital grade rating of the receptacle.

6. Operasi

The Leviton 1254-R 4-in-1 Receptacle operates like any standard electrical outlet. Simply insert the plug of your electrical device into one of the four available receptacles. Ensure the plug is fully inserted for a secure connection. The extra heavy-duty, T-type triple-wipe bronze contacts provide maximum performance and a strong grip on cords.

7. Pemeliharaan

This industrial-grade receptacle requires minimal maintenance. Periodically inspect the receptacle for any signs of damage, such as cracks, discoloration, or loose connections. If any damage is observed, turn off power at the circuit breaker and replace the receptacle immediately. Clean the surface with a soft, dry cloth. Do not use abrasive cleaners or solvents.

8. Penyelesaian masalah

MasalahKemungkinan PenyebabLarutan
Tidak ada daya di stopkontak.Pemutus sirkuit terputus atau sekering putus. Sambungan kabel longgar.Check and reset the circuit breaker or replace the fuse. Turn off power and inspect wiring connections for tightness.
Device plug feels loose in the outlet.Worn contacts (unlikely for new industrial grade). Incorrect plug type.Ensure the plug is fully inserted. If the issue persists, and the receptacle is old, consider replacement. Verify plug compatibility.
Receptacle is warm to the touch.Overload on the circuit. Loose wiring connection.Disconnect some devices to reduce load. Turn off power and check wiring connections. If warming persists, consult an electrician.

9. Informasi Garansi

Leviton products are backed by a limited warranty. For specific warranty terms and conditions applicable to the 1254-R receptacle, please refer to the warranty documentation included with your purchase or visit the official Leviton websitus. Simpan bukti pembelian Anda untuk klaim garansi.

10. Dukungan

For technical assistance, product information, or customer support, please visit the official Leviton website or contact their customer service department. Contact details can typically be found on the product packaging or the Leviton weblokasi.

Leviton Weblokasi: www.leviton.com

Dokumen Terkait - 1254-R

Praview Manual Instalasi dan Pengoperasian Stopkontak GFCI Leviton dengan Port USB
Panduan lengkap untuk memasang dan mengoperasikan Stopkontak GFCI Leviton dengan Port USB, termasuk petunjuk pemasangan kabel, peringatan keselamatan, prosedur pengujian, dan informasi garansi.
Praview Panduan Komprehensif tentang Cara Memasang dan Menguji Stopkontak GFCI Pintar Leviton:
Petunjuk langkah demi langkah untuk memasang dan menguji stopkontak Leviton Smart GFCI (model D2GF1, D2GF2). Pelajari tentang fungsi GFCI, pemasangan kabel, pemecahan masalah, dan tindakan pencegahan keselamatan.
Praview Panduan Instalasi dan Pengujian Stopkontak GFCI Leviton SmartlockPro
Panduan lengkap untuk memasang dan menguji stopkontak Ground Fault Circuit Interrupter (GFCI) Leviton SmartlockPro. Mencakup tindakan pencegahan keselamatan, pemasangan kabel, pemecahan masalah, dan fitur produk.
Praview Panduan Pemasangan dan Pengujian Stopkontak GFCI Leviton
Panduan lengkap tentang cara memasang dan menguji Leviton SmartLock Pro GFCI Receptacle, termasuk petunjuk pemasangan kabel, tindakan pencegahan keselamatan, dan kiat pemecahan masalah.
Praview Panduan Pemasangan Rel DIN GFCI Leviton GFNT1-DIN/GFNT2-DIN
Panduan lengkap untuk memasang dan menguji Stopkontak GFCI Pemasangan Rel DIN GFNT1-DIN dan GFNT2-DIN Leviton, termasuk petunjuk pemasangan kabel, tindakan pencegahan keselamatan, dan pemecahan masalah.
Praview Leviton Smart Wallbox Sensors: Elevate Your Sensing Control Options
Discover Leviton Smart Wallbox Sensors for commercial applications, offering occupancy/vacancy sensing, dimming, switching, energy savings, and code compliance for offices, meeting rooms, and lobbies. Learn about key features and benefits.