The Bryant/Carrier Humidifier Water Panel P110-3545 is an original factory replacement component designed to maintain optimal humidity levels in your home. This water panel is crucial for the efficient operation of your humidifier, ensuring proper moisture evaporation and distribution.
Regular replacement of the water panel is recommended annually to ensure consistent performance and prevent mineral buildup that can reduce efficiency.

Image 1: Bryant/Carrier Humidifier Water Panel P110-3545. This image displays the humidifier water panel, which is a rectangular, porous pad designed for water absorption and evaporation within a humidifier unit.
Compatible Humidifier Models:
- Pembawa: HUMCCLBP2217, HUMCCLBP2317, HUMCALBP2317, HUMCCLBP2417, HUMCALBP2417, HUMCCLFP1218, HUMCCLFP1318, HUMCALFP1318
- Bryant: HUMBBLBP2217, HUMBBLBP2317, HUMBALBP2317, HUMBBLBP2417, HUMBALBP2417, HUMBBLFP1218, HUMBBLFP1318, HUMBALFP1318
- Totaline: P110-LBP2217, P110-LBP2317, P110-LBP2417, P110-LFP1218, P110-LFP1318
- Aprilaire: 350, 360, 560, 560A, 568, 600, 700, 700A, 700M, 760, 760A, 768 (Equivalent to Aprilaire #35)
- Honeywell: HE260A/B, HE265A/B, HE360A/B, ME360, HE365A/B
- Lennox: WB217, WP218, HCWB2-17, HCWP2-18
2. Informasi Keselamatan
Always disconnect power to the humidifier unit before performing any maintenance or replacement procedures. Failure to do so may result in electrical shock or injury. Wear appropriate personal protective equipment, such as gloves, if handling old water panels that may contain mineral deposits.
3. Pengaturan dan Pemeriksaan Awal
Upon receiving your new water panel, inspect it for any signs of damage during shipping. Ensure the panel dimensions match the requirements of your humidifier model. The water panel should be clean and free of debris before installation.
4. Prinsip Operasional
The water panel functions as the evaporative medium within your humidifier. Water flows over the panel, and as warm air from your HVAC system passes through it, the water evaporates, adding humidity to the air. This humidified air is then distributed throughout your home. The porous design of the panel maximizes the surface area for efficient evaporation.
5. Maintenance: Water Panel Replacement
Annual replacement of the water panel is crucial for maintaining your humidifier's efficiency and preventing the buildup of mineral deposits, which can impede water absorption and airflow. Follow these steps for replacement:
- Putuskan Daya: Turn off the power supply to your humidifier unit at the circuit breaker or by unplugging it.
- Access Humidifier: Open the humidifier's access panel or cover. Refer to your specific humidifier model's manual for exact instructions on how to open it.
- Remove Old Water Panel: Carefully remove the old water panel and its frame (if applicable). Note the orientation of the old panel for correct installation of the new one. Dispose of the old panel responsibly.
- Clean Humidifier: While the unit is open, it is a good opportunity to clean any mineral deposits or debris from the humidifier's water tray and housing.
- Install New Water Panel: Place the new Bryant/Carrier P110-3545 water panel into the frame, ensuring it is correctly seated and oriented.
- Berkumpul kembali: Reinstall the water panel assembly into the humidifier and securely close the access panel or cover.
- Pulihkan Daya: Restore power to the humidifier unit.
Visual Guide for Replacement:
Video 1: This video demonstrates the replacement process for Bryant/Carrier humidifier water panels, including models HUMCCLBP, HUMBBSBP, 2217, 2317, 2417, and HUMBALBP. It provides a visual guide to assist with the steps outlined above.
Video 2: This short video provides an overview of the Water Panel 35 Humidifier Filter Pad, highlighting its features and design for creating indoor comfort.
6. Penyelesaian masalah
- Reduced Humidifier Output: If your humidifier is not producing sufficient humidity, check if the water panel is clogged with mineral deposits. A heavily scaled panel will not absorb water effectively. Replace the water panel if it shows significant buildup.
- Bau Tidak Biasa: Stagnant water or excessive mineral buildup on the water panel can sometimes cause odors. Ensure the humidifier is clean and replace the water panel as recommended.
- Kebocoran Air: While not directly caused by the water panel itself, ensure the panel is correctly seated in its frame and the humidifier housing is properly closed after replacement to prevent leaks.
7. Spesifikasi
| Fitur | Detil |
|---|---|
| Nama Model | Hal. 110-3545 |
| Dimensi (Perkiraan) | 10 x 13 x 1-1/2 inches (25.4 x 33.02 x 3.81 cm) |
| Bahan | Plastic (evaporative media) |
| Berat | Sekitar 1.01 pon (0.46 kg) |
| Kesesuaian | Bryant, Carrier, Totaline, Aprilaire, Honeywell, Lennox humidifiers (see list above) |
| Penggantian yang Direkomendasikan | Setiap tahun |
8. Informasi Garansi
For specific warranty details regarding the Bryant/Carrier Humidifier Water Panel P110-3545, please refer to the documentation provided with your original humidifier unit or contact the manufacturer directly. Warranties typically cover manufacturing defects and not normal wear and tear or damage due to improper installation or maintenance.
9. Dukungan
If you encounter issues or have questions not covered in this manual, please contact your authorized Bryant/Carrier dealer or a qualified HVAC technician for assistance. When contacting support, have your humidifier model number and the water panel model number (P110-3545) readily available.