GIMA 28211

Buku Panduan Pengguna Aspirator Hisap GIMA 28211 Super Vega

Model: 28211 | Brand: GIMA

1. Pendahuluan

The GIMA 28211 Super Vega Suction Aspirator is a compact and reliable medical device designed for the aspiration of bodily fluids such as mucus, catarrh, or blood. It is suitable for nasal, oral, and tracheal aspiration in both adults and children. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your device.

GIMA 28211 Super Vega Suction Aspirator main unit

Image 1.1: The GIMA 28211 Super Vega Suction Aspirator, showing the main unit with collection jar, tubing, and control panel.

2. Informasi Keselamatan

  • Bacalah manual ini secara lengkap sebelum mengoperasikan perangkat.
  • Pastikan perangkat diletakkan di permukaan yang stabil dan rata selama pengoperasian.
  • Jangan merendam unit utama di dalam air atau cairan lainnya.
  • Only use accessories and spare parts approved by GIMA.
  • Periksa kabel daya secara berkala untuk melihat apakah ada kerusakan. Jangan gunakan jika rusak.
  • Jauhkan perangkat dari jangkauan anak-anak dan orang yang tidak berwenang.
  • This device is intended for medical use and should be operated by trained individuals or under medical supervision.
  • Pastikan ventilasi yang memadai di sekitar perangkat selama pengoperasian.

3. Isi Paket

Verifikasi bahwa semua komponen ada dan tidak rusak saat dibuka kemasannya:

  • GIMA 28211 Super Vega Suction Aspirator main unit
  • 1000 ml autoclavable collection jar with lid
  • Suction tubing set
  • Penyaring bakteri
  • Kabel listrik
  • Panduan Pengguna
Collection jar and lid

Image 3.1: 1000 ml collection jar with lid.

Penyaring bakteri

Image 3.2: Bacterial filter.

Kabel listrik

Image 3.3: Power cord.

4. Pengaturan

  1. Penempatan: Place the aspirator on a stable, flat, and dry surface, ensuring adequate space for ventilation.
  2. Connect Collection Jar: Securely attach the 1000 ml collection jar to the designated holder on the side of the main unit. Ensure the lid is tightly sealed.
  3. Hubungkan Tabung:
    • Connect one end of the short silicone tube to the 'VACUUM' port on the collection jar lid.
    • Connect the other end of this short tube to the suction inlet on the main unit (usually marked 'SUCTION' or similar).
    • Connect one end of the longer silicone tube to the 'PATIENT' port on the collection jar lid. This end will connect to the patient catheter.
  4. Install Bacterial Filter: Insert the bacterial filter between the 'VACUUM' port on the collection jar lid and the suction inlet of the main unit. This prevents fluid overflow and protects the pump. Ensure the filter is correctly oriented according to any arrows on its casing.
  5. Sambungan Daya: Connect the power cord to the aspirator's power inlet and then plug it into a suitable electrical outlet (220-230 V/50-60 Hz).
GIMA 28211 Super Vega Suction Aspirator fully assembled

Image 4.1: The aspirator fully assembled and ready for operation.

5. Petunjuk Pengoperasian

  1. Nyalakan: Press the green power switch (marked with 'I/O') located on the front panel to turn on the device. The indicator light should illuminate.
  2. Sesuaikan Hisapan: Use the 'SUCTION CONTROL' knob on the front panel to adjust the desired vacuum level. Turn clockwise to increase suction and counter-clockwise to decrease it.
  3. Monitor Vakum: Observe the vacuum gauge on the front panel to ensure the desired suction pressure is achieved. The gauge displays pressure in mmHg and kPa.
  4. Connect Catheter: Attach the appropriate sterile suction catheter to the free end of the patient tubing.
  5. Perform Aspiration: Carefully perform the aspiration procedure as directed by a medical professional.
  6. Matikan: After use, press the power switch to turn off the device.
Control panel of GIMA 28211 Super Vega Suction Aspirator

Image 5.1: Close-up of the control panel, showing the power switch, vacuum gauge, and suction control knob.

6. Perawatan dan Pembersihan

Regular cleaning and maintenance are crucial for the device's longevity and hygienic operation.

6.1. Collection Jar

  • Empty the collection jar after each use or when the fluid level approaches the maximum fill line.
  • The 1000 ml collection jar is autoclavable at 121°C. An optional jar is available that can be autoclaved at 134°C.
  • Wash the jar and lid thoroughly with warm water and a mild detergent. Rinse well and sterilize as appropriate.
  • Ensure the safety float valve in the lid is clean and moves freely to prevent overflow.

6.2. Tubing and Filter

  • Clean the suction tubing after each use by aspirating clean water through it.
  • Replace the bacterial filter regularly, especially if it becomes wet, discolored, or shows signs of contamination. The filter is disposable.

6.3. Unit Utama

  • Wipe the exterior of the main unit with a soft cloth dampened with a mild disinfectant.
  • Jangan gunakan pembersih atau pelarut yang bersifat abrasif.
  • Ensure no liquids enter the internal components of the device.

7. Penyelesaian masalah

MasalahKemungkinan PenyebabLarutan
Perangkat tidak menyalaNo power supply; damaged power cord; faulty power switchCheck power cord connection and wall outlet. Inspect power cord for damage. If problem persists, contact technical support.
No or weak suctionLoose connections; clogged tubing/catheter; full collection jar; faulty bacterial filter; pump issueCheck all tubing connections for leaks. Clear any blockages in tubing/catheter. Empty collection jar. Replace bacterial filter. If problem persists, contact technical support.
Fluid overflow into main unitCollection jar overfilled; faulty safety float valve; bacterial filter not installed or cloggedEmpty collection jar immediately. Check float valve for proper movement. Ensure bacterial filter is correctly installed and not clogged.
Kebisingan yang tidak biasa selama pengoperasianLoose components; internal pump issueEnsure all external components are secure. If noise persists, discontinue use and contact technical support.

8. Spesifikasi

  • Model: GIMA 28211 Super Vega
  • Volume Operasitage: 220-230V / 50-60Hz
  • Konsumsi Daya: 106W
  • Collection Jar Capacity: 1000 ml
  • Dimensi (P x L x T): Ukuran 35x21x18 cm
  • Berat: Sekitar 3.34 kg
  • Pengatur Vakum: Continuously adjustable
  • Autoclavable Jar: 121°C (optional 134°C)
  • Isolasi: Electrical and thermal insulating plastic body

9. Garansi dan Dukungan

Information regarding the specific warranty period for the GIMA 28211 Super Vega Suction Aspirator is not provided in this document. Please refer to your purchase documentation or contact your local GIMA distributor or customer service for warranty details and technical support.

For assistance, please have your model number (28211) and purchase date available.

Dokumen Terkait - 28211

Praview Panduan Pengguna dan Petunjuk Teknis Unit Penghisap Baterai GIMA SUPERVEGA
Dokumen ini memberikan petunjuk pengoperasian yang komprehensif, pedoman keselamatan, spesifikasi teknis, dan prosedur perawatan untuk GIMA SUPERVEGA BATTERY SUCTION UNIT (Model 28193), sebuah perangkat penghisap medis profesional.
Praview GIMA TOBI MANUALE Suction Aspirator - User Manual & Technical Specifications
Comprehensive user manual and technical specifications for the GIMA TOBI MANUALE Suction Aspirator. Learn about its features, safety instructions, cleaning, maintenance, and troubleshooting.
Praview GIMA S/S Bierer Aspiration Tube - User Manual & Specifications (Models 28262, 28264)
Official user manual and technical specifications for the GIMA S/S Bierer Aspiration Tube (Models 28262 and 28264). Details intended use, features, procedure, cleaning, sterilization, operating conditions, and manufacturer information.
Praview Panduan Pengguna Probe Oksimeter Denyut GIMA - Spesifikasi Teknis dan Panduan Penggunaan
Panduan pengguna komprehensif untuk probe oksimeter denyut GIMA, mencakup spesifikasi produk, tujuan penggunaan, manfaat klinis, perawatan, pembersihan, disinfeksi, persyaratan lingkungan, dan informasi kompatibilitas elektromagnetik (EMC). Termasuk nomor model ESA0015, ESC0029, dan lainnya.
Praview GIMA KYOLING® Manual Suction Pump with Filter - Product Information
Comprehensive guide for the GIMA KYOLING® manual suction pump with filter, detailing its features, specifications, usage instructions, maintenance procedures, and troubleshooting tips for medical professionals.
Praview Lanset Pengaman Tekanan Aktif GIMA (PA) - Alat Medis untuk Darah Kapilerampbahasa inggris
Informasi tentang Lancet Keamanan Aktif Tekanan GIMA (Model PA), perangkat steril sekali pakai untuk pengambilan sampel darah kapilerampling. Meliputi tujuan penggunaan, petunjuk, peringatan, penyimpanan, dan pembuangan.