Perkenalan
The PowerWalker VFI AT series is an online Uninterruptible Power Supply (UPS) system designed to provide reliable power protection for critical electronic devices. This manual provides essential information for the safe and efficient operation of your PowerWalker VFI 3000 AT UPS, model 10122182.
Petunjuk Keselamatan Penting
Harap baca dan ikuti semua petunjuk dengan saksama sebelum memasang, mengoperasikan, atau melakukan servis pada UPS. Simpan manual ini untuk referensi di masa mendatang.
- UPS ini berisi bahan berbahaya.tagJangan mencoba membongkar unit ini. Perbaikan hanya boleh dilakukan oleh personel yang berkualifikasi.
- UPS harus dihubungkan ke stopkontak listrik AC yang diarde.
- Jangan halangi lubang ventilasi. Pastikan aliran udara di sekitar UPS memadai.
- Do not install the UPS in direct sunlight, near heat sources, or in environments with excessive dust, humidity, or corrosive substances.
- The internal batteries are not user-replaceable. Contact qualified service personnel for battery replacement.
- In case of fire, use a dry chemical fire extinguisher. Water can be dangerous.
Isi Paket
Pastikan semua barang yang tercantum di bawah ini termasuk dalam paket Anda. Jika ada barang yang hilang atau rusak, hubungi dealer Anda.
- PowerWalker VFI 3000 AT UPS Unit
- User Manual (dokumen ini)
- Kabel Komunikasi USB
- Kabel Masukan Daya
- CD perangkat lunak (jika ada)
Produk Selesaiview
Panel Depan

Gambar 1: Depan view of the PowerWalker VFI 3000 AT UPS. This image displays the main chassis, ventilation grilles, and the front control panel with its LCD screen and buttons.

Gambar 2: Terperinci view of the UPS front panel. The LCD screen shows input/output voltage and load status. Below the screen are control buttons: ON, OFF, ENTER, and ESC, used for navigating menus and controlling the unit.
The front panel features an LCD display that provides real-time information about the UPS status, including input/output voltage, battery level, and load capacity. Control buttons allow for navigation through the display menus and basic operation of the unit.
Panel Belakang

Gambar 3: Belakang view of the PowerWalker VFI 3000 AT UPS. This panel includes multiple Type F earthing contact outlets for connecting protected devices, cooling fans, a main power input, and communication ports (USB, RS-232, and an optional slot for network card).
The rear panel provides the necessary connections for input power, output to protected devices, and communication interfaces. It includes four Type F earthing contact outlets, a terminal output, USB and RS-232 communication ports, and slots for optional accessories like network cards.
Petunjuk Pengaturan
1. Penempatan
- Place the UPS on a flat, stable surface.
- Ensure the environment is well-ventilated and free from excessive dust or moisture.
- Maintain at least 20 cm (8 inches) of clearance from the rear and sides of the UPS for proper airflow.
- Avoid placing the UPS near heat-emitting appliances.
2. Menghubungkan ke Daya
- Connect the provided power input cable to the UPS input receptacle on the rear panel.
- Plug the other end of the power input cable into a grounded wall outlet.
- Allow the UPS to charge for at least 8 hours before initial use to ensure optimal battery performance.
3. Menghubungkan Perangkat
- Plug your critical devices (e.g., computers, servers, network equipment) into the Type F output receptacles on the rear panel of the UPS.
- Ensure that the total load connected to the UPS does not exceed its rated capacity (2700W for this model).
- For devices requiring terminal output, connect them according to electrical safety standards.
4. Permulaan Awal
- After connecting the UPS to AC power and allowing initial charging, press and hold the ON button on the front panel for approximately 2 seconds.
- The UPS will perform a self-test, and the LCD display will illuminate, indicating operational status.
- The UPS is now providing protected power to the connected devices.
Mengoperasikan UPS
Menyalakan/Mematikan
- Untuk Mengaktifkan: Tekan dan tahan tombol ON tombol selama 2 detik.
- Mematikan: Tekan dan tahan tombol MATI button for 2 seconds. The UPS will shut down, and power to connected devices will cease.
Memahami Layar LCD
The LCD display provides critical information about the UPS status. Use the MEMASUKI Dan Bahasa Inggris buttons to navigate through different display screens, which may include:
- Masukan Voltage dan Frekuensi
- Volume Keluarantage dan Frekuensi
- Tingkat Pengisian Baterai
- Persen Bebantage
- Operating Mode (Online, Battery, Bypass)
- Kode Kesalahan (jika ada)
Operasi Cadangan Baterai
Jika terjadi pemadaman listriktage atau volume signifikantage fluctuation, the UPS will automatically switch to battery power to provide continuous power to connected devices. An audible alarm may sound, and the LCD will indicate "Battery Mode." The duration of battery backup depends on the load connected and the battery charge level.
Perangkat Lunak Komunikasi
For advanced monitoring and management, install the provided communication software on a computer connected to the UPS via the USB or RS-232 port. This software allows for scheduled shutdowns, remote monitoring, and detailed event logging.
Pemeliharaan
Perawatan Baterai
- Ensure the UPS is connected to AC power at all times to keep the batteries fully charged.
- Perform a battery self-test periodically (e.g., once every 3 months) using the UPS front panel controls or communication software to verify battery health.
- Batteries have a limited lifespan. If the battery backup time significantly decreases, contact qualified service personnel for replacement.
Pembersihan
- Putuskan sambungan UPS dari daya AC dan semua perangkat yang terhubung sebelum membersihkan.
- Use a soft, dry cloth to wipe the exterior of the UPS.
- Do not use liquid or aerosol cleaners, as they may damage the unit.
- Periodically clean the ventilation grilles to prevent dust buildup, which can impede airflow and cause overheating.
Penyimpanan
- If storing the UPS for an extended period, ensure the batteries are fully charged.
- Store the UPS in a cool, dry place.
- Recharge the batteries every 3 months during storage to prevent deep discharge and prolong battery life.
Penyelesaian Masalah
Refer to the table below for common issues and their solutions. If the problem persists, contact technical support.
| Masalah | Kemungkinan Penyebab | Larutan |
|---|---|---|
| UPS tidak menyala. | No AC input power. Daya baterai rendah. | Periksa sambungan kabel daya dan stopkontak di dinding. Allow UPS to charge for several hours. |
| UPS berbunyi bip terus menerus dalam mode normal. | Kondisi kelebihan beban. Kesalahan internal. | Reduce the load by unplugging non-essential devices. Hubungi dukungan teknis. |
| Waktu pencadangan singkat. | Baterai tidak terisi penuh. Batteries reaching end of life. Beban berlebih. | Allow UPS to charge for 8+ hours. Contact service for battery replacement. Mengurangi beban yang terhubung. |
| UPS is noisy. | Normal fan operation (especially under load). Halangan pada kipas. | This is normal for online UPS units. Ensure proper ventilation. Check for and clear any obstructions around fans. |
Spesifikasi
| Fitur | Detil |
|---|---|
| Model | 10122182 |
| Kapasitas | 3000 VA / 2700 W |
| Masukan Voltage | 300 Volt (nominal) |
| Volume Keluarantage | 300 Volt (nominal) |
| Jenis Baterai | Baterai Timbal-Asam, AGM |
| Baterai Termasuk | Ya |
| Outlet Keluaran | 4x Type F Earthing Contact, Terminal Output |
| Faktor Bentuk | Menara |
| Dimensi (P x L x T) | Ukuran 41.6x19.6x34.2 cm |
| Berat | 21 kg |
| Bahan | Plastik |
| Ampmarah | 9 Amps |
Garansi dan Dukungan
The PowerWalker VFI 3000 AT UPS is covered by a manufacturer's warranty. For detailed warranty terms and conditions, please refer to the warranty card included with your product or visit the official PowerWalker weblokasi.
For technical support, service inquiries, or to report any issues, please contact your local dealer or PowerWalker customer service. Have your model number (10122182) and purchase information ready when contacting support.