1. Pendahuluan
Thank you for choosing the Mirage Life 12+ Mini Split Air Conditioner. This manual provides comprehensive instructions for the safe and efficient installation, operation, and maintenance of your new unit. Please read this manual thoroughly before using the appliance and keep it for future reference. Proper use and care will ensure optimal performance and longevity of your air conditioner.
2. Informasi Keselamatan
Your safety and the safety of others are very important. Please read and follow all safety messages outlined in this manual to prevent serious injury or property damage. Always adhere to local electrical codes and regulations.
Tindakan pencegahan umum:
- Only qualified personnel should perform installation, repair, or maintenance. Improper installation can result in electric shock, fire, or water leakage.
- Ensure the power supply matches the unit's specifications (110V). Do not use extension cords or multi-outlet adapters.
- Jangan memasukkan jari atau benda apa pun ke dalam saluran masuk/keluar udara.
- Jangan mengoperasikan unit dengan tangan basah.
- Jauhkan bahan yang mudah terbakar dari unit.
- If the unit emits smoke or an unusual smell, immediately turn off the power and contact a service technician.
3. Produk Lebihview
The Mirage Life 12+ is a 1-ton mini split air conditioner designed for efficient cooling and heating. It consists of an indoor unit, an outdoor unit, and a remote control for convenient operation.
Komponen:
- Unit dalam ruangan: Mounted inside the room, responsible for air distribution.
- Unit Luar Ruangan: Mounted outside, responsible for heat exchange.
- Kontrol Jarak Jauh: Used to control the unit's functions and settings.

Gambar 3.1: Depan view of the Mirage Life 12+ Mini Split indoor unit. This image shows the sleek white design of the indoor air handler, featuring the 'Mirage' logo on the left and 'LIFE 12+' branding on the right.

Gambar 3.2: Sudut view of the Mirage Life 12+ Mini Split indoor unit. This perspective highlights the depth and side profile of the indoor unit, providing a better understanding of its physical form.

Figure 3.3: Remote control for the Mirage Life 12+ Mini Split. The remote features a digital display at the top showing the set temperature, and various buttons for functions like ON/OFF, Mode, Temp, Fan Speed, Swing, Timer, Sleep, Turbo, and Display.

Figure 3.4: Dimensions of the Mirage Life 12+ Mini Split indoor unit. This image illustrates the unit's measurements: 171cm in length, 59cm in depth, and 92cm in height.
4. Pengaturan dan Instalasi
Installation should only be performed by a qualified and certified HVAC technician. Incorrect installation can lead to serious issues, including electric shock, fire, and water leakage.
4.1 Daftar Periksa Pra-instalasi:
- Lokasi: Choose a location for the indoor unit that allows for even air distribution and easy drainage. The outdoor unit should be placed in a well-ventilated area, away from direct sunlight and obstructions.
- Catu Daya: Ensure a dedicated 110V power circuit is available for the unit.
- Peralatan: Gather all necessary tools, including drills, wrenches, vacuum pump, manifold gauge, and safety equipment.
4.2 Pemasangan Unit Dalam Ruangan:
- Pemasangan Plat Pemasangan: Securely fasten the mounting plate to the wall, ensuring it is level and can support the unit's weight.
- Bor Lubang Dinding: Drill a hole (typically 65mm-75mm diameter) through the wall for the refrigerant piping and drainage hose.
- Sambungan Pipa Refrigeran: Connect the refrigerant pipes (liquid and gas lines) to the indoor unit. Ensure connections are tight to prevent leaks.
- Sambungan Selang Pembuangan: Connect the drainage hose, ensuring it slopes downwards to allow for proper water flow.
- Kabel listrik: Connect the electrical wires according to the wiring diagram provided with the unit.
- Pasang Unit Dalam Ruangan: Carefully mount the indoor unit onto the mounting plate.
4.3 Outdoor Unit Installation:
- Lokasi dan Pemasangan: Place the outdoor unit on a stable, level surface or a dedicated mounting bracket. Ensure adequate clearance for airflow.
- Sambungan Pipa Refrigeran: Connect the refrigerant pipes from the indoor unit to the outdoor unit.
- Membersihkan dengan penyedot debu dan mengisi daya: Evacuate the refrigerant lines using a vacuum pump to remove air and moisture. If necessary, charge the system with the correct amount of R-32 refrigerant.
- Sambungan Listrik: Connect the power supply and communication wires to the outdoor unit as per the wiring diagram.
4.4 Sambungan Listrik:
The Mirage Life 12+ operates on 110 Volts. All electrical wiring must comply with national and local electrical codes. Ensure the circuit breaker is off before making any electrical connections. Use appropriate gauge wiring for the power supply.
5. Petunjuk Pengoperasian
Your Mirage Life 12+ Mini Split is controlled via the wireless remote control. Familiarize yourself with the remote's functions for optimal use.
5.1 Fungsi Kontrol Jarak Jauh:
- Tombol ON/OFF: Tekan untuk menghidupkan atau mematikan unit.
- Tombol MODE: Berganti-ganti melalui mode pengoperasian: Otomatis, Dingin, Kering, Kipas, Panas.
- Tombol TEMP +/- : Menyesuaikan pengaturan suhu yang diinginkan.
- Tombol KECEPATAN KIPAS: Memilih kecepatan kipas: Otomatis, Rendah, Sedang, Tinggi.
- Tombol SWING: Controls the vertical airflow direction (louver swing).
- Tombol TIMER ON/OFF: Sets the time for the unit to automatically turn on or off.
- Tombol TIDUR: Mengaktifkan mode tidur untuk pengoperasian yang tenang dan penghematan energi selama tidur.
- Tombol TURBO: Mengaktifkan pendinginan atau pemanasan cepat untuk penyesuaian suhu yang cepat.
- Tombol TAMPILKAN: Turns the indoor unit's display light on or off.
5.2 Mode Operasi:
- Modus Keren: Untuk mendinginkan ruangan. Atur suhu yang diinginkan.
- Mode Panas: Untuk memanaskan ruangan. Atur suhu yang diinginkan.
- Mode Kering: Mengurangi kelembapan di dalam ruangan.
- Modus Kipas: Sirkulasikan udara tanpa pendinginan atau pemanasan.
- Mode otomatis: The unit automatically selects the operating mode (Cool, Heat, Fan) based on the room temperature and your set temperature.
5.3 Setting Temperature:
Tekan tombol SUHU + or TEMPUR - buttons on the remote control to increase or decrease the desired temperature. The temperature range is typically between 16°C and 30°C (60°F and 86°F).
5.4 Timer Function:
To set the timer for automatic ON/OFF, press the PENANDA WAKTU MENYALA or TIMER MATI tombol. Gunakan SUHU +/- buttons to adjust the desired time, then press the timer button again to confirm.
6. Pemeliharaan
Regular maintenance ensures the efficient and long-lasting operation of your Mirage Life 12+ Mini Split. Always turn off the power supply to the unit before performing any maintenance.
6.1 Pembersihan Rutin:
- Filter Udara: Clean the air filters every two weeks or more frequently if the unit is used heavily or in dusty environments. Remove the filters, wash them with lukewarm water and mild detergent, rinse thoroughly, and allow them to dry completely before reinserting.
- Indoor Unit Surface: Lap permukaan unit indoor dengan kain lembut dan kering. Untuk kotoran membandel, gunakanamp cloth with mild detergent, then wipe dry. Do not use harsh chemicals or abrasive cleaners.
- Unit Luar Ruangan: Periodically clear any debris (leaves, dirt) from around the outdoor unit. Ensure the coils are free from obstructions. For thorough cleaning of outdoor coils, it is recommended to contact a professional.
6.2 Seasonal Maintenance:
- Sebelum Musim Panas/Musim Dingin: Mintalah teknisi yang berkualifikasi untuk memeriksa kadar refrigeran, sambungan listrik, dan kinerja sistem secara keseluruhan.
- Pemeriksaan Drainase: Ensure the drainage hose is not clogged and water can flow freely.
7. Penyelesaian masalah
Sebelum menghubungi dukungan pelanggan, silakan lihat tabel berikut untuk masalah umum dan solusinya.
| Masalah | Kemungkinan Penyebab | Larutan |
|---|---|---|
| Unit tidak menyala. | Tidak ada aliran listrik; Pemutus sirkuit terputus; Baterai remote control habis. | Periksa sambungan daya; Setel ulang pemutus sirkuit; Ganti baterai remote control. |
| Pendinginan/pemanasan tidak memadai. | Filter udara kotor; Unit luar ruangan tersumbat; Pengaturan mode yang salah; Refrigeran rendah. | Clean air filters; Clear obstructions from outdoor unit; Select correct mode; Contact technician for refrigerant check. |
| Kebisingan yang tidak biasa. | Komponen longgar; Kipas terhalang; Masalah kompresor. | Check for loose parts; Remove any obstructions; Contact technician. |
| Kebocoran air dari unit dalam-ruang. | Clogged drainage hose; Improper installation. | Clear drainage hose; Contact technician for re-installation check. |
| Kontrol jarak jauh tidak berfungsi. | Baterai habis; Terdapat penghalang antara remote dan unit; Remote berada di luar jangkauan. | Replace batteries; Remove obstructions; Operate within range. |
8. Spesifikasi Teknis
| Fitur | Nilai |
|---|---|
| Merek | fatamorgana |
| Nomor Model | 2 (MMI12HABWCATME1/MMI12HABWCATMI1) |
| Warna | Putih |
| Dimensi Produk | Ukuran 59x171x92 cm |
| Kapasitas | 1ton |
| Daya/Wattage | 110 |
| Jil.tage | 110 Volt |
| Tingkat Kebisingan | 60dB |
| Fitur Khusus | Pendinginan Cepat |
| Berat Barang | 40 kg |
| Pendingin | R-32 |
| Sumber Daya | Kabel listrik |
| Jenis Garansi | Seumur hidup |
9. Garansi dan Dukungan Pelanggan
The Mirage Life 12+ Mini Split Air Conditioner comes with a Garansi Seumur Hidup, as specified by the manufacturer. Please retain your proof of purchase for warranty claims.
For technical assistance, troubleshooting beyond this manual, or warranty service, please contact Mirage customer support. Refer to the product packaging or the official Mirage websitus untuk informasi kontak terkini.
Note: Unauthorized service or repairs may void your warranty.