DALY LFP24S

DALY LiFePo4 72V 40A 24S Smart BMS Instruction Manual

1. Pendahuluan

This instruction manual provides essential information for the safe and effective use of your DALY LiFePo4 72V 40A 24S Smart Battery Management System (BMS). This BMS is designed to protect and optimize the performance of 24-series LiFePo4 battery packs, commonly used in energy storage, electric vehicles, electric tools, and solar systems. Please read this manual thoroughly before installation and operation.

2. Informasi Keselamatan

Bekerja dengan vol tinggitage battery systems requires extreme caution. Failure to follow safety instructions can result in serious injury, property damage, or death. Always adhere to the following safety guidelines:

3. Isi Paket

Verifikasi bahwa semua item ada dalam paket:

Contents of the DALY Smart BMS package, including the BMS unit, cables, and manual.

Gambar 3.1: Contohample of package contents for the DALY Smart BMS.

4. Produk Lebihview

The DALY Smart BMS provides comprehensive protection for your LiFePo4 battery pack, including overcurrent, overcharge, overdischarge, short circuit, and temperature protection. It features a robust design with injection patent technology and a patent shell for waterproof, dustproof, shockproof, and anti-static properties.

Atas view of the DALY LiFePo4 24S 72V 40A Smart BMS, showing the main terminals P- and B-, and communication ports.

Gambar 4.1: Atas view of the DALY Smart BMS, highlighting main connections and communication interfaces.

Samping view of the DALY LiFePo4 24S 72V 40A Smart BMS with dimensions: 128mm (5.0 inches) length, 66mm (2.59 inches) width, and 18mm (0.7 inches) thickness. Continuous discharge current is 40A.

Figure 4.2: Dimensions and continuous discharge current rating of the DALY Smart BMS.

5. Pengaturan dan Instalasi

Careful installation is crucial for the proper functioning of the BMS. Follow these steps precisely:

  1. Siapkan Paket Baterai: Ensure your LiFePo4 battery pack consists of 24 cells in series, with each cell rated at 3.2V.
  2. Hubungkan Kabel Balanced:
    • Before connecting the balance wires to the BMS, ensure all balance wires are correctly welded to their respective battery cell terminals.
    • Connect the balance wire harness to the BMS balance port. Ensure the B- wire (total negative pole) is connected first, followed by B1, B2, and so on, up to B24 (total positive pole).
    • Verifikasi voltage setiap sel dan total voltage using a multimeter before proceeding.
  3. Hubungkan Kabel Daya Utama:
    • Connect the main negative wire from the battery pack to the B- terminal on the BMS.
    • Connect the main negative wire for the load/charger to the P- terminal on the BMS.
  4. Hubungkan Sensor Suhu NTC: Plug the NTC sensor into the designated port on the BMS. Position the sensor appropriately on the battery pack to monitor temperature.
  5. Connect Communication Modules (Optional):
    • For Bluetooth connectivity, plug the Bluetooth module into the UART port.
    • For PC communication, connect the UART cable to the UART port and then to a USB-UART converter (if needed) to your computer.
  6. Activate the BMS: After all connections are secure, activate the BMS by pressing the activation button on the power board or by connecting the charger to the battery pack.
Detailed wiring diagram for the DALY Smart BMS, showing connections for battery cells, main power, charger, motor/load, and communication modules.

Figure 5.1: Wiring diagram for the DALY Smart BMS. Ensure all connections are made correctly.

For visual guidance on wiring and connections, refer to the official DALY website tutorial videos: DALY BMS Tutorial Videos.

6. Petunjuk Pengoperasian

The DALY Smart BMS allows monitoring and parameter modification via Bluetooth app or PC software.

6.1. Bluetooth App Operation

Connect the Bluetooth module to the BMS UART port. Download the DALY BMS app from your smartphone's app store. Open the app, search for your BMS, and connect. The initial password for the app is 123456. Through the app, you can:

DALY Smart BMS connected via Bluetooth to a smartphone app, displaying battery status and parameters.

Figure 6.1: Monitoring the BMS via the Bluetooth smartphone application.

6.2. Pengoperasian Perangkat Lunak PC

Connect the BMS to your computer using the UART cable and a USB-UART converter. Install the DALY BMS PC software. The PC software offers more detailed control and data logging capabilities, allowing for advanced parameter configuration and firmware updates.

DALY Smart BMS connected to a computer via UART, showing the PC software interface for monitoring and configuration.

Figure 6.2: Interacting with the BMS using PC software via UART connection.

Penting: The factory default parameters are general. It is essential to review and adjust these parameters to match the specific capacity (Ah) of your battery pack. Incorrect parameter settings can lead to inaccurate state-of-charge readings and potentially damage the battery. The percentage of remaining power will be inaccurate if the capacity is not set correctly.

7. Pemeliharaan

To ensure the longevity and optimal performance of your DALY Smart BMS:

8. Penyelesaian masalah

Jika Anda mengalami masalah dengan DALY Smart BMS Anda, pertimbangkan langkah-langkah pemecahan masalah umum berikut:

MasalahKemungkinan PenyebabLarutan
BMS not activating/no power outputIncorrect wiring; BMS not activated; low battery voltage.Verify all wiring connections (B-, P-, balance wires). Press the activation button or connect the charger to activate. Check battery voltage; if too low, charge the battery.
Masalah koneksi BluetoothBluetooth module not properly connected; app issues; interference.Ensure the Bluetooth module is securely plugged into the UART port. Restart the app and try reconnecting. Check for other Bluetooth devices causing interference. Ensure the app is updated.
Inaccurate State of Charge (SOC)Battery capacity parameter not set correctly in the app/software.Access the app or PC software and set the battery pack's actual Ah capacity.
Overcharge/Overdischarge protection tripping prematurelyProtection parameters set too low/high; faulty cell.Review and adjust overcharge/overdischarge voltage parameters in the app/software to match your battery specifications. Check individual cell voltages for imbalances.

If the problem persists after attempting these steps, please contact DALY customer support for further assistance.

9. Spesifikasi

FiturSpesifikasi
Nomor ModelLFP24S
Komposisi Sel BateraiLiFePo4 (Litium Besi Fosfat)
Konfigurasi Seri24S (24 cells in series)
Volume Nominaltage72V (for 3.2V rated cells)
Arus Debit Kontinyu40A
Antarmuka KomunikasiUART (Bluetooth module included)
Dimensi Produk (P x L x T)5.03 x 2.6 x 0.51 inci (128 x 66 x 18 mm)
Berat Barang13.4 ons
PabrikanDongguan Daly Electronics Co., Ltd

10. Garansi dan Dukungan

DALY Electronics is committed to providing high-quality products and customer satisfaction. This product comes with lifetime technical support.