L3 Campus Stackable Managed Switch
“
Spesifikasi
- Model: Omada Campus Stackable L3 Managed Switch
- Front Panel: Mode Selection Button, Management Port, LED,
Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
DIPIMPIN - Indikasi LED:
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
disconnected or not working properly) - PWR2: Green On (switch powered by PWR1 and PWR2 connected),
Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
dengan baik) - LED SYS FAN: Green On (all fans work properly), Yellow On (not
all fans work properly) - MGMT: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port) - MST: On (device linked to port), Flashing (transmitting or
receiving data), Off (no device linked to port)
- PWR1*: Green On (switch powered by PWR1), Off (PWR2
Petunjuk Penggunaan Produk
Bab 2: Instalasi
Sebelum memulai proses instalasi, pastikan Anda memiliki semuanya
the necessary tools and follow safety precautions.
- Isi Paket: Check all items mentioned in
paketnya. - Tindakan pencegahan keamanan: Ikuti panduan untuk
memastikan instalasi yang aman. - Alat Instalasi: Gather all tools required
untuk instalasi. - Instalasi Produk: Ikuti langkah demi langkah
instructions provided in the manual for successful
instalasi.
Bab 3: Koneksi
After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.
Bab 4: Konfigurasi
Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
kebutuhan.
Tanya Jawab Umum
Q: What should I do if the LED indications show an error?
A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
bagian dalam manual untuk bantuan lebih lanjut.
“
Solusi Jaringan Bisnis
Panduan Instalasi
Omada Campus Stackable L3 Managed Switch
Tentang Panduan Instalasi ini
Panduan Instalasi ini menjelaskan karakteristik perangkat keras, metode instalasi, dan hal-hal yang harus diperhatikan selama instalasi. Panduan Instalasi ini disusun sebagai berikut: Bab 1 Pendahuluan Bab ini menjelaskan komponen eksternal sakelar. Bab 2 Instalasi Bab ini mengilustrasikan cara memasang sakelar. Bab 3 Koneksi Bab ini mengilustrasikan cara melakukan koneksi fisik sakelar. Bab 4 Konfigurasi Bab ini mengilustrasikan cara mengonfigurasi sakelar. Lampiran A Pemecahan Masalah Lampiran B Spesifikasi
Hadirin
Panduan Instalasi ini untuk:
Insinyur Jaringan
Administrator Jaringan
Konvensi
· Beberapa model yang ditampilkan dalam panduan ini mungkin tidak tersedia di negara atau wilayah Anda. Untuk informasi penjualan lokal, kunjungi https://www.omadanetworks.com/.
· Gambar-gambar dalam Bab 2, Bab 3, dan Bab 4 hanya untuk tujuan demonstrasi. Tampilan sakelar Anda mungkin berbeda dari yang digambarkan.
· Perhitungan anggaran PoE didasarkan pada pengujian laboratorium. Anggaran daya PoE aktual tidak dijamin dan akan bervariasi sebagai akibat dari keterbatasan klien dan faktor lingkungan.
· Panduan ini menggunakan format khusus untuk menyorot pesan-pesan khusus. Tabel berikut mencantumkan ikon-ikon pemberitahuan yang digunakan di seluruh panduan ini.
Ingatkan untuk berhati-hati. Perhatian menunjukkan potensi yang dapat menyebabkan kerusakan perangkat.
Ingatkan untuk memperhatikan. Catatan tersebut berisi informasi yang berguna untuk penggunaan produk yang lebih baik.
Dokumen Terkait
Panduan Pengguna dan Panduan Referensi CLI produk tersedia di Pusat Unduhan. Untuk mendapatkan informasi produk terbaru, kunjungi official websitus: https://support.omadanetworks.com/document/.
Isi
Bab 1 Pendahuluan ———————- 01
1.1 Produk Lebih dariview ………………………………………………………..01 1.2 Penampilan………………………………………………………………..01
Bab 2 Instalasi ———————- 12
2.1 Isi Kemasan ……………………………………………………….12 2.2 Tindakan Pencegahan Keamanan ……………………………………………………….12 2.3 Alat Instalasi ………………………………………………………..14 2.4 Instalasi Produk ………………………………………………..14
Bab 3 Koneksi ———————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
Bab 4 Konfigurasi ——————– 27
4.1 Konfigurasi Berakhirview……… ...
Lampiran A Pemecahan Masalah —————- 32
Lampiran B Spesifikasi —————— 33
Omada Campus Stackable L3 Managed Switch
Bab 1 PENDAHULUAN
1.1 Produk Lebih dariview
Dirancang untuk perusahaan dan campus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. Exampfile termasuk menyalakan kamera jaringan, titik akses LAN nirkabel, telepon IP, hub jaringan, komputer tertanam, dll.
1.2 Penampilan
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Tombol Pemilihan Mode
Port Manajemen
DIPIMPIN
Console Port USB2.0 Port (Type-C/RJ45)
Pelabuhan 1G RJ45
10G SFP+ Slot LED
The front panel of S6500-48G6XF is shown as the following figure.
Tombol Pemilihan Mode
Port Manajemen
DIPIMPIN
Console Port USB2.0 Port (Type-C/RJ45)
Pelabuhan 1G RJ45
10G SFP+ Slot LED
Pendahuluan 01
Omada Campus Stackable L3 Managed Switch
Indikasi LED
PWR1*
PWR2
Hijau Aktif
Mati
Hijau Aktif
Kuning Aktif**
Mati
Hijau Aktif
Mati
Mati
Indikasi
Sakelar ini ditenagai oleh PWR1. PWR2 terputus atau tidak berfungsi dengan benar.
Sakelar ini didukung oleh PWR1. PWR1 dan PWR2 terhubung.*
Sakelar ini ditenagai oleh PWR2. PWR1 terputus atau tidak berfungsi dengan benar.
Sakelar dimatikan atau PWR1 dan PWR2 tidak berfungsi dengan benar.
LED SYS FAN
Manajemen Manajemen
Waktu Standar Timur
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(When the SPEED LED is on)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(Saat LED STK menyala)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***
Indikasi
Berkedip: Sakelar berfungsi dengan baik. Menyala atau Mati: Sakelar tidak berfungsi dengan baik.
Hijau menyala: Semua kipas bekerja dengan baik. Kuning menyala: Tidak semua kipas bekerja dengan baik.
Menyala: Perangkat terhubung ke port. Berkedip: Mengirim atau menerima data. Mati: Tidak ada perangkat yang terhubung ke port.
Aktif: Perangkat berfungsi sebagai sakelar utama dalam topologi tumpukan atau bekerja secara individual. Nonaktif: Perangkat berfungsi sebagai sakelar anggota dalam topologi tumpukan.
Hijau Menyala: Berjalan pada kecepatan 1000 Mbps, tetapi tidak ada aktivitas. Hijau Berkedip: Berjalan pada kecepatan 1000 Mbps dan sedang mengirim atau menerima data. Kuning Menyala: Berjalan pada kecepatan 10Mbps/100 Mbps, tetapi tidak ada aktivitas. Kuning Berkedip: Berjalan pada kecepatan 10Mbps/100 Mbps dan sedang mengirim atau menerima data. Mati: Tidak ada perangkat yang terhubung ke port terkait.
Aktif: Nomor port menunjukkan ID unit dalam topologi tumpukan.
Hijau Menyala: Berjalan pada 10 Gbps, tetapi tidak ada aktivitas. Hijau Berkedip: Berjalan pada 10 Gbps dan mengirimkan atau menerima data. Kuning Menyala: Berjalan pada 1 Gbps, tetapi tidak ada aktivitas. Kuning Berkedip: Berjalan pada 1 Gbps dan mengirimkan atau menerima data. Mati: Tidak ada perangkat yang terhubung ke port terkait.
*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**Bila PWR1 dan PWR2 berfungsi baik dan sakelar diberi daya oleh PWR1, diperlukan waktu 10-20 detik agar LED PWR2 (kuning) padam setelah PWR2 dicabut.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
02 Pendahuluan
Omada Campus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.
Tombol Pemilihan Mode
Port Manajemen
LED Console Port USB2.0 Port (Type-C/RJ45)
Pelabuhan 1G RJ45
10G SFP+ Slot LED
Panel depan S6500-48GP6XF ditunjukkan seperti gambar berikut.
Tombol Pemilihan Mode
Port Manajemen
LED Console Port USB2.0 Port (Type-C/RJ45)
Pelabuhan 1G RJ45
10G SFP+ Slot LED
The front panel of S6500-24M4Y is shown as the following figure.
Tombol Pemilihan Mode
Port Manajemen
LED Console Port USB2.0 Port (Type-C/RJ45)
Pelabuhan 2.5G RJ45
25G SFP28 Slot LED
The front panel of S6500-24MPP4Y is shown as the following figure.
Tombol Pemilihan Mode
Port Manajemen
LED Console Port USB2.0 Port (Type-C/RJ45)
Pelabuhan 2.5G RJ45
25G SFP28 Slot LED
Pendahuluan 03
Omada Campus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.
Tombol Pemilihan Mode
Port Manajemen
LED Console Port USB2.0 Port (Type-C/RJ45)
Pelabuhan 2.5G RJ45
The front panel of S6500-48MPP6Y is shown as the following figure.
25G SFP28 Slot LED
Tombol Pemilihan Mode
Port Manajemen
LED Console Port USB2.0 Port (Type-C/RJ45)
Pelabuhan 2.5G RJ45
25G SFP28 Slot LED
LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
Manajemen Manajemen
Waktu Standar Timur
Indikasi
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Berkedip: Sakelar berfungsi dengan baik. Menyala atau Mati: Sakelar tidak berfungsi dengan baik.
Hijau menyala: Semua kipas bekerja dengan baik. Kuning menyala: Tidak semua kipas bekerja dengan baik.
Menyala: Daya PoE yang tersisa adalah 7 W. Berkedip: Daya PoE yang tersisa tetap 7 W setelah LED ini menyala selama 2 menit. Mati: Daya PoE yang tersisa > 7 W.
Menyala: Perangkat terhubung ke port. Berkedip: Mengirim atau menerima data. Mati: Tidak ada perangkat yang terhubung ke port.
Aktif: Perangkat berfungsi sebagai sakelar utama dalam topologi tumpukan atau bekerja secara individual. Nonaktif: Perangkat berfungsi sebagai sakelar anggota dalam topologi tumpukan.
04 Pendahuluan
Omada Campus Stackable L3 Managed Switch
DIPIMPIN
Indikasi
Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(When the SPEED LED is on)
Hijau Menyala: Berjalan pada kecepatan 1000 Mbps, tetapi tidak ada aktivitas. Hijau Berkedip: Berjalan pada kecepatan 1000 Mbps dan sedang mengirim atau menerima data. Kuning Menyala: Berjalan pada kecepatan 10Mbps/100 Mbps, tetapi tidak ada aktivitas. Kuning Berkedip: Berjalan pada kecepatan 10Mbps/100 Mbps dan sedang mengirim atau menerima data. Mati: Tidak ada perangkat yang terhubung ke port terkait.
Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(When the SPEED LED is on)
Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.
Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(Saat LED STK menyala)
Aktif: Nomor port menunjukkan ID unit dalam topologi tumpukan.
Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(Saat LED PoE menyala)
Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port
Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***
Hijau Menyala: Berjalan pada 10 Gbps, tetapi tidak ada aktivitas. Hijau Berkedip: Berjalan pada 10 Gbps dan mengirimkan atau menerima data. Kuning Menyala: Berjalan pada 1 Gbps, tetapi tidak ada aktivitas. Kuning Berkedip: Berjalan pada 1 Gbps dan mengirimkan atau menerima data. Mati: Tidak ada perangkat yang terhubung ke port terkait.
Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***
Hijau Menyala: Berjalan pada kecepatan 25 Gbps, tetapi tidak ada aktivitas. Hijau Berkedip: Berjalan pada kecepatan 25 Gbps dan sedang mengirim atau menerima data. Kuning Menyala: Berjalan pada kecepatan 1 Gbps/10 Gbps, tetapi tidak ada aktivitas. Kuning Berkedip: Berjalan pada kecepatan 1 Gbps/10 Gbps dan sedang mengirim atau menerima data. Mati: Tidak ada perangkat yang terhubung ke port yang sesuai.
*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Pendahuluan 05
Omada Campus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
Port Manajemen
DIPIMPIN
Console Port USB3.0 Port
(RJ45/Tipe-C)
Pemilihan Mode
Tombol
10G SFP+ Slot (Port 1-26)
The front panel of S7500-48XF4C is shown as the following figure.
LED 25G SFP28 Slot (Port 27-32)
Tombol Pemilihan Mode
Port Manajemen
LED Console Port USB3.0 Port (Type-C/RJ45)
10G SFP+ Slot (Port 1-48)
The front panel of S7500-24Y4C is shown as the following figure.
100G QSFP28 Slot LED (Port 49-52)
Port Manajemen
DIPIMPIN
Port USB3.0
Pelabuhan Konsol
(RJ45/Tipe-C)
Tombol Pemilihan Mode
Slot SFP25 28G
DIPIMPIN
(Pelabuhan 1-24)
The front panel of S7500-48Y8C is shown as the following figure.
Slot QSFP100 28G (Port 25-28)
LED Mode Selection Button
25G SFP28 Slot (Port 1-48)
06 Pendahuluan
Slot QSFP100 28G (Port 49-56)
Omada Campus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.
Tombol Pemilihan Mode
Port Manajemen LED
Port USB3.0
Console Port (Type-C/RJ45)
Slot QSFP28 100G
DIPIMPIN
Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.
LED Indication LED
PWR1* PWR2
KIPAS SISTEM
Manajemen Manajemen
Waktu Standar Timur
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(Saat LED SPD menyala)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)
Indikasi
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Berkedip: Sakelar berfungsi dengan baik. Menyala atau Mati: Sakelar tidak berfungsi dengan baik.
Hijau: Semua kipas bekerja dengan baik. Kuning: Tidak semua kipas bekerja dengan baik.
Menyala: Perangkat terhubung ke port. Berkedip: Mengirim atau menerima data. Mati: Tidak ada perangkat yang terhubung ke port.
Catatan:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
Aktif: Perangkat berfungsi sebagai sakelar utama dalam topologi tumpukan atau bekerja secara individual. Nonaktif: Perangkat berfungsi sebagai sakelar anggota dalam topologi tumpukan.
Hijau Menyala: Berjalan pada 10 Gbps, tetapi tidak ada aktivitas. Hijau Berkedip: Berjalan pada 10 Gbps dan mengirimkan atau menerima data. Kuning Menyala: Berjalan pada 1 Gbps, tetapi tidak ada aktivitas. Kuning Berkedip: Berjalan pada 1 Gbps dan mengirimkan atau menerima data. Mati: Tidak ada perangkat yang terhubung ke port terkait.
Hijau Menyala: Berjalan pada kecepatan 25 Gbps, tetapi tidak ada aktivitas. Hijau Berkedip: Berjalan pada kecepatan 25 Gbps dan sedang mengirim atau menerima data. Kuning Menyala: Berjalan pada kecepatan 1 Gbps/10 Gbps, tetapi tidak ada aktivitas. Kuning Berkedip: Berjalan pada kecepatan 1 Gbps/10 Gbps dan sedang mengirim atau menerima data. Mati: Tidak ada perangkat yang terhubung ke port yang sesuai.
Pendahuluan 07
Omada Campus Stackable L3 Managed Switch
DIPIMPIN
Indikasi
Port 27-32 of S7500-26XF6Y ***
(Saat LED SPD menyala)
Hijau Menyala: Berjalan pada kecepatan 25 Gbps, tetapi tidak ada aktivitas. Hijau Berkedip: Berjalan pada kecepatan 25 Gbps dan sedang mengirim atau menerima data. Kuning Menyala: Berjalan pada kecepatan 1 Gbps/10 Gbps, tetapi tidak ada aktivitas. Kuning Berkedip: Berjalan pada kecepatan 1 Gbps/10 Gbps dan sedang mengirim atau menerima data. Mati: Tidak ada perangkat yang terhubung ke port yang sesuai.
Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)
Hijau Menyala: Berjalan pada 100 Gbps, tetapi tidak ada aktivitas. Hijau Berkedip: Berjalan pada 100 Gbps dan mengirimkan atau menerima data. Kuning Menyala: Berjalan pada 40 Gbps, tetapi tidak ada aktivitas. Kuning Berkedip: Berjalan pada 40 Gbps dan mengirimkan atau menerima data. Mati: Tidak ada perangkat yang terhubung ke port terkait.
Catatan:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)
Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(Saat LED STK menyala)
Aktif: Nomor port menunjukkan ID unit dalam topologi tumpukan.
*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Port Manajemen Dirancang untuk menghubungkan perangkat untuk manajemen melalui web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.
08 Pendahuluan
Omada Campus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature
Model
1000 juta
2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB
RJ45 Port RJ45 Port Slot
celah
celah
Pelabuhan
Pelabuhan Pelabuhan
S6500-24G4XF
24
/
4
/
/
S6500-48G6XF
48
/
6
/
/
S6500-24GP4XF
24
/
4
/
/
S6500-48GP6XF
48
/
6
/
/
S6500-24M4Y
/
24
/
4
/
S6500-24MPP4Y
/
24
/
4
/
S6500-48M6Y
/
48
/
6
/
S6500-48MPP6Y
/
48
/
6
/
S7500-26XF6Y
/
/
26
6
/
S7500-48XF4C
/
/
48
/
4
S7500-24Y4C
/
/
/
24
4
S7500-48Y8C
/
/
/
48
8
S7500-32C
/
/
/
/
32
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
1
2
2
Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Kensington Security Slot Grounding Terminal Power Socket
Locking Strap Slot
Catatan: PWR1 merupakan catu daya utama dan memiliki prioritas lebih tinggi daripada PWR2.
Pendahuluan 09
Omada Campus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Slot Keamanan Kensington
DIPIMPIN
Terminal Pembumian
Modul Catu Daya
DIPIMPIN
Locking Strap Slot
Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
Terminal Pembumian
DIPIMPIN
Power Supply Module Locking Strap Slot
DIPIMPIN
Slot Keamanan Kensington
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.
Panel belakang S7500-48Y8C ditunjukkan pada gambar berikut. Gambar ini hanya untuk tujuan demonstrasi. Tampilan sakelar Anda mungkin berbeda dari yang ditampilkan.
Terminal Pembumian
DIPIMPIN
DIPIMPIN
Mengunci Tali
celah
Modul Catu Daya
10 Pendahuluan
ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED
Omada Campus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.
dipimpin LED
Locking Strap Slot
Modul Catu Daya Slot Keamanan Kensington
Terminal Pembumian
DIPIMPIN
Locking Strap Slot
Modul Catu Daya
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.
Pendahuluan 11
Omada Campus Stackable L3 Managed Switch
Bab 2 Instalasi
2.1 Isi Paket
Pastikan paket berisi item berikut. Silakan hubungi distributor Anda, jika salah satu item yang terdaftar rusak atau hilang. Angka-angka hanya untuk demonstrasi. Item yang sebenarnya mungkin berbeda dalam penampilan dan jumlah dari yang digambarkan.
Mengalihkan
Kabel Daya dan Kabel Konsol
Panduan Instalasi
Solusi Jaringan Bisnis
Panduan Instalasi
Omada Campus Stackable L3 Managed Switch
Braket Pemasangan, Sekrup dan Kaki Karet
2.2 Tindakan pencegahan keselamatan
Untuk menghindari kerusakan perangkat dan cedera tubuh akibat penggunaan yang tidak tepat, Anda harus mematuhi aturan berikut.
Tindakan Pencegahan Keamanan Matikan daya selama pemasangan. Kenakan gelang anti-ESD, dan pastikan gelang tersebut bersentuhan dengan kulit dengan baik dan
dibumikan dengan baik. Gunakan hanya kabel daya yang disertakan dengan sakelar. Pastikan tegangan suplaitage sesuai dengan spesifikasi yang tertera pada panel belakang
sakelar. Pastikan sakelar dipasang di lingkungan yang berventilasi baik dan lubang ventilasinya tidak
diblokir. Jangan membuka atau melepas penutup sakelar. Sebelum membersihkan perangkat, matikan catu daya. Jangan membersihkannya dengan kain yang basah, dan jangan pernah
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Persyaratan Situs
Suhu/Kelembapan
12 Instalasi
Omada Campus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
Debu yang terkumpul pada sakelar dapat diserap oleh listrik statis dan mengakibatkan kontak yang buruk pada titik kontak logam. Beberapa tindakan telah diambil untuk mencegah listrik statis pada perangkat, tetapi listrik statis yang terlalu kuat dapat menyebabkan kerusakan fatal pada elemen elektronik pada papan sirkuit internal. Untuk menghindari efek listrik statis pada pengoperasian sakelar, perhatikan hal-hal berikut: Bersihkan debu pada perangkat secara teratur, dan jaga kebersihan udara dalam ruangan. Pastikan perangkat terhubung ke tanah dengan baik dan pastikan listrik statis telah ditransfer. Interferensi Elektromagnetik
Elemen elektronik termasuk kapasitansi dan induktansi pada perangkat dapat terpengaruh oleh gangguan eksternal, seperti emisi yang dihantarkan oleh kopling kapasitansi, kopling induktansi, dan kopling impedansi. Untuk mengurangi gangguan, pastikan untuk mengambil langkah-langkah berikut: Gunakan catu daya yang dapat secara efektif menyaring gangguan dari jaringan listrik. Jauhkan perangkat dari perangkat berfrekuensi tinggi dan berarus kuat seperti pemancar radio
stasiun. Gunakan pelindung elektromagnetik bila perlu. Proteksi Petir
Instalasi 13
Omada Campus Stackable L3 Managed Switch
Vol sangat tinggitagArus ini dapat dihasilkan secara instan ketika terjadi petir dan udara pada jalur pelepasan listrik dapat langsung memanas hingga 20,000 °C. Karena arus instan ini cukup kuat untuk merusak perangkat elektronik, tindakan proteksi petir yang lebih efektif harus diambil. Pastikan rak dan perangkat telah dibumikan dengan baik. Pastikan soket listrik mempunyai kontak yang baik dengan tanah. Pertahankan sistem perkabelan yang wajar dan hindari petir yang diinduksi. Gunakan sinyal SPD (Surge Protective Device) saat memasang kabel di luar ruangan.
Catatan: Untuk langkah-langkah proteksi petir yang lebih rinci, silakan merujuk ke Panduan Proteksi Petir dari: https://support.omadanetworks.com/r/1004/. Lokasi Pemasangan
When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only. This equipment is not suitable for use in locations where children are likely to be present. The rack or workbench is flat, stable, and sturdy enough to support the weight of 9.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Alat Instalasi
Kabel pembungkus pergelangan tangan pencegah ESD obeng Phillips
Catatan: Alat-alat ini tidak disertakan dengan produk kami. Jika diperlukan, Anda dapat membelinya secara terpisah.
2.4 Instalasi Produk
Sakelar ini dirancang dengan fitur pembuangan panas dari depan ke belakang. Saat berfungsi, udara bersirkulasi seperti yang ditunjukkan di bawah ini. Untuk pembuangan panas yang lebih baik, harap pasang perangkat di lingkungan yang berventilasi baik dan sisakan celah 5 hingga 10 cm di sekeliling perangkat.
14 Instalasi
Gambar 2-1
Sirkulasi Udara
Omada Campus Stackable L3 Managed Switch
Instalasi Desktop
Untuk memasang perangkat di desktop, ikuti langkah-langkah berikut:
1. Letakkan perangkat pada permukaan datar yang cukup kuat untuk menopang seluruh berat perangkat dengan segala kelengkapannya.
2. Lepaskan kertas pendukung perekat dari kaki karet.
3. Pasangkan kaki karet ke bagian bawah perangkat untuk mencegahnya tergelincir saat diletakkan di atas meja.
Gambar 2-2
Instalasi Desktop
Kaki Bagian Bawah Takik Perangkat
Pemasangan Rak
Paket ini berisi 6 pasang braket pemasangan rak yang berbeda, gambarnya ditampilkan di bawah dan mungkin berbeda dari produk sebenarnya.
Gambar 2-3
Braket Pemasangan
Grup Lubang Sekrup 2
Bracket D Bracket C Bracket B Bracket A
Grup Lubang Sekrup 1
Grup Lubang Sekrup 3
Braket F
Screw Hole Group 4-2 (for device with 420mm depth)
Grup Lubang Sekrup 5
Lubang sekrup
Grup 4-1
Screw Hole Group 4-3
(for device with 380mm depth)
(for device with
460mm depth)
Kurung E
Instalasi 15
Omada Campus Stackable L3 Managed Switch
Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:
Metode
Demonstrasi
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)
Jarak Rak
(For device with a depth of 380mm)
Jarak Rak
(For device with a depth of 420mm)
Jarak Rak
(For device with a depth of 460mm)
498-640mm 538-680mm 578-720mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)
477-498mm 517-538mm 557-578mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)
429-477mm 469-517mm 509-557mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)
410-429mm 450-469mm 490-509mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)
357-410mm 397-450mm 437-490mm
Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)
282-410mm 322-450mm 362-490mm
16 Instalasi
Omada Campus Stackable L3 Managed Switch
Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)
555-936mm 555-936mm 555-936mm
Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)
743-1121mm 743-1121mm 743-1121mm
Untuk memasang perangkat, ikuti petunjuk yang dijelaskan di bawah ini:
1. Attach the M6 nuts to the racks.
Gambar 2-4
Mengamankan Mur M6
ukuran ×8
2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.
Gambar 2-5
Memasang Braket pada Rak
or
3. Attach the brackets A & D/F to the switch with the provided M3 screws.
Instalasi 17
Omada Campus Stackable L3 Managed Switch
Gambar 2-6
Memasang Braket pada Switch
4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.
Gambar 2-7
Memasang Sakelar pada Rak
Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.
18 Instalasi
Omada Campus Stackable L3 Managed Switch
Pemasangan Modul Catu Daya
S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.
Gambar 2-8
Penampilan Modul Catu Daya
Konektor Kabel Daya AC
FAN
Klip Penahan
Pegangan Ekstraksi
DIPIMPIN
Locking Strap Slot Release Handle
Jika Anda perlu menambahkan satu modul catu daya lagi, ikuti langkah-langkah berikut:
1. Gunakan tali pergelangan tangan anti-ESD, dan pastikan tali tersebut bersentuhan baik dengan kulit dan terhubung ke ground dengan baik.
2. Tekan gagang pelepasan modul dengan satu tangan, lalu tahan bagian bawah modul dengan tangan lainnya. Dorong modul secara perlahan di sepanjang rel pemandu slot.
3. Lepaskan pegangan ekstraksi untuk memasang modul catu daya pada tempatnya.
Gambar 2-9
Memasang Modul Catu Daya
Pegangan Rilis
Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Gunakan tali pergelangan tangan anti-ESD, dan pastikan tali tersebut bersentuhan baik dengan kulit dan terhubung ke ground dengan baik.
Instalasi 19
Omada Campus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap
Jika Anda perlu melepas modul catu daya, ikuti langkah-langkah berikut:
1. Gunakan tali pergelangan tangan anti-ESD, dan pastikan tali tersebut bersentuhan baik dengan kulit dan terhubung ke ground dengan baik.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Pemasangan Modul Kipas
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
Gambar 2-11 Penampakan Modul Kipas
DIPIMPIN
20 Instalasi
Extraction Handle Retainer Clips Release Handle
Omada Campus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
2. Tekan gagang ekstraksi modul dengan satu tangan, dan tarik gagang ekstraksi hingga
Modul sepenuhnya keluar dari sasis.
Gambar 2-12 Melepas Modul Kipas yang Rusak
3. Press the extraction handle of a new fan module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Instalasi 21
Omada Campus Stackable L3 Managed Switch
Bab 3 Koneksi
3.1 Pelabuhan Ethernet
Hubungkan port Ethernet dari sakelar ke komputer dengan kabel RJ45 seperti yang ditunjukkan gambar berikut.
Gambar 3-1
Menghubungkan Port RJ45
Port RJ45
Kabel RJ45
3.2 10G SFP+/25G SFP28/100G QSFP28 Slot
The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module
Gambar 3-2
Inserting the Fiber Module
Slot Fiber Module
3.3 Port Konsol
CLI (Command Line Interface) memungkinkan Anda untuk mengelola sakelar, sehingga Anda dapat memuat CLI setelah menghubungkan PC atau Terminal ke port konsol pada sakelar melalui kabel (kabel konsol RJ45 disediakan, sedangkan kabel Tipe-C tidak disediakan)
Hubungkan port konsol RJ45 perangkat dengan komputer Anda menggunakan kabel konsol seperti yang ditunjukkan gambar berikut.
Koneksi 22
Gambar 3-3
Menghubungkan Port Konsol (RJ45).
Omada Campus Stackable L3 Managed Switch
Hubungkan port konsol Tipe-C perangkat dengan komputer Anda menggunakan kabel Tipe-C (tidak disediakan) seperti yang ditunjukkan gambar berikut.
Gambar 3-4
Menghubungkan Port Konsol (USB).
Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Verifikasi Instalasi
Setelah menyelesaikan instalasi, verifikasi item berikut: Harus ada jarak 5 hingga 10 cm di sekitar perangkat untuk ventilasi dan pastikan aliran udara
cukup. Voltage dari catu daya memenuhi persyaratan volume inputtage perangkat. Soket daya, perangkat, dan rak diarde dengan baik. Perangkat tersambung dengan benar ke perangkat jaringan lainnya.
Koneksi 23
Omada Campus Stackable L3 Managed Switch
3.5 Nyalakan
Colokkan konektor perempuan dari kabel daya yang disediakan ke soket daya perangkat dan colokkan konektor positif ke stopkontak seperti yang ditunjukkan gambar berikut. Pastikan bahwa voltage dari catu daya memenuhi persyaratan volume inputtage (100-240 V~ 50/60Hz).
Gambar 3-5
Menghubungkan ke Sumber Daya Listrik
Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.
3.6 Inisialisasi
Setelah perangkat dihidupkan, perangkat akan memulai Uji Mandiri Penyalaan. Serangkaian tes berjalan secara otomatis untuk memastikan perangkat berfungsi dengan baik. Selama waktu ini, indikator LED-nya akan merespons dalam urutan berikut:
1. Indikator LED PWR menyala sepanjang waktu. LED SYS dan indikator LED dari semua port mati.
2. Setelah sekitar satu menit, LED SYS dan indikator LED semua port akan berkedip sebentar lalu mati.
3. Beberapa detik kemudian, indikator LED SYS akan berkedip, yang menunjukkan inisialisasi yang berhasil.
3.7 Topologi Tumpukan
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:
Mengalihkan
Model yang Kompatibel
Kuantitas
S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
Koneksi 24
Omada Campus Stackable L3 Managed Switch
S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y
S7500-26XF6Y S7500-26XF6Y
S7500-48XF4C S7500-48XF4C
S7500-24Y4C S7500-24Y4C
S7500-48Y8C S7500-48Y8C
S7500-32C
S7500-32C
2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)
Ada tiga struktur topologi tumpukan untuk skenario yang berbeda, silakan bangun topologi yang tepat sesuai dengan kebutuhan Anda:
1. Topologi Rantai: Topologi rantai relatif sederhana dan tidak memerlukan sambungan kabel antara unit pertama dan terakhir. Cocok untuk penumpukan jarak jauh, tetapi keandalannya relatif rendah.
Gambar 3-6
Topologi Rantai
Penumpukan Port Grup 2
Penumpukan Port Grup 1
…
2. Topologi Ring: Topologi ring memiliki keandalan yang lebih tinggi dibandingkan dengan topologi rantai. Ketika salah satu rantai dalam topologi ring terputus, topologi ring menjadi topologi rantai, tetapi seluruh sistem stack masih dapat bekerja secara normal. Topologi ring memerlukan koneksi kabel antara unit pertama dan terakhir, sehingga tidak cocok untuk stacking jarak jauh.
Gambar 3-7
Topologi Cincin
Penumpukan Port Grup 2
Penumpukan Port Grup 1
…
Koneksi 25
Omada Campus Stackable L3 Managed Switch
3. Topologi Bintang: Topologi bintang menghubungkan sakelar ke sakelar utama pusat, oleh karena itu, dapat secara signifikan meningkatkan laju penerusan data antara sakelar anggota sambil menyediakan manajemen terpadu.
Gambar 3-8
Topologi Bintang
Penumpukan Port Grup 2
Penumpukan Port Grup 3
Penumpukan Port Grup 1
…
Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.
Koneksi 26
Omada Campus Stackable L3 Managed Switch
Bab 4 Konfigurasi
4.1 Konfigurasi Berakhirview
Sakelar mendukung dua opsi konfigurasi:
Mode Standalone: Konfigurasikan dan kelola switch secara terpisah. Mode Controller: Konfigurasikan dan kelola perangkat jaringan secara terpusat. Disarankan dalam
jaringan berskala besar, yang terdiri dari perangkat massal seperti titik akses, sakelar, dan gerbang.
Catatan: Saat sakelar diubah dari Mode Standalone ke Mode Pengontrol, konfigurasi sakelar akan hilang. Untuk detailnya, lihat dokumen terkait di pusat unduhan resmi kami websitus: https://support.omadanetworks.com/product/.
4.2 Mode Mandiri
Dalam Mode Standalone, gunakan komputer untuk mengkonfigurasi dan mengelola switch menggunakan GUI (Graphical User Interface) atau CLI (command-line interface).
Gambar 4-1
Topologi untuk Mode Standalone
Mengalihkan
PC
Menggunakan GUI
1. Untuk mengakses halaman manajemen sakelar, pastikan sakelar dan komputer berada dalam subnet yang sama. Buka browser dan ketik alamat IP sakelar di bidang alamat, lalu tekan tombol Enter.
Jika sakelar memperoleh alamat IP dari server DHCP (biasanya gateway), temukan alamat IP sakelar di server DHCP.
Jika tidak, gunakan alamat IP default 192.168.0.1 untuk meluncurkan halaman manajemen sakelar.
2. Saat pertama kali masuk, atur nama pengguna dan kata sandi untuk melindungi jaringan dan perangkat Anda dengan lebih baik. Setelah itu, sistem akan secara otomatis mengarahkan Anda kembali ke antarmuka masuk untuk mengautentikasi dengan kredensial yang baru dibuat.
3. Setelah berhasil login, akan muncul halaman utama. Anda dapat mengklik menu di sisi atas dan kiri untuk mengonfigurasi fungsi yang sesuai.
Untuk konfigurasi terperinci, lihat Panduan Pengguna dan Panduan CLI. Panduan dapat ditemukan di pusat unduhan resmi kami websitus: https://support.omadanetworks.com/product/.
Menggunakan CLI Siapkan koneksi Telnet atau SSH untuk mengakses sakelar melalui CLI.
Konfigurasi 27
Omada Campus Stackable L3 Managed Switch
Gunakan port konsol untuk mengakses sakelar. Saat menggunakan port konsol, jalankan program emulasi terminal (seperti Hyper Terminal) pada PC dan konfigurasikan program emulasi terminal sebagai berikut:
Tingkat Baud 38400bps
Bit Data 8
Paritas Tidak ada
Hentikan Bit 1
Kontrol Aliran Tidak Ada
Untuk konfigurasi terperinci, lihat Panduan Pengguna dan Panduan CLI. Panduan dapat ditemukan di pusat unduhan resmi kami websitus: https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.
4.3 Mode Pengontrol
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.
Via Omada Pro Hardware Controller (C5300)
Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).
Gambar 4-2
Manage the network via Omada Pro Hardware Controller (C5300)
Saklar Gerbang
Omada Pro Hardware Controller (C5300) EAP
28 Konfigurasi
Bahasa Inggris
Bahasa Inggris
Klien
Omada Campus Stackable L3 Managed Switch
Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.
1. Temukan alamat IP gateway. Buka baris perintah di PC Anda dan masukkan ipconfig. Dalam daftar hasil, temukan Default Gateway, yang juga merupakan alamat IP gateway.
2. Luncurkan web peramban dan masukkan alamat IP gateway. Masuk ke gateway web halaman. Lalu masuk ke Jaringan > LAN > Daftar Klien DHCP untuk menemukan alamat IP pengontrol Anda sesuai dengan alamat MAC-nya.
3. Masukkan alamat IP pengontrol Anda di bilah alamat untuk membukanya web halaman.
4. Pada Pengontrol Omada Pro web halaman, ikuti panduan untuk menyelesaikan pengaturan cepat.
5. Setelah pengaturan cepat, halaman login akan muncul. Masukkan nama pengguna dan kata sandi yang telah Anda buat dan klik Masuk. Kemudian Anda dapat mengkonfigurasi pengontrol lebih lanjut.
6. Jika Anda ingin mengelola perangkat dari jarak jauh, ikuti langkah-langkah berikut:
a. Pastikan Cloud Access diaktifkan pada kontroler Anda. Secara default, Cloud Access diaktifkan. Pastikan LED Cloud berkedip perlahan.
b. Luncurkan web browser dan masukkan https://omada.tplinkcloud.com di bilah alamat. Masukkan ID TP-Link dan kata sandi Anda untuk masuk. Klik + Tambah Pengontrol dan pilih Pengontrol Perangkat Keras untuk menambahkan pengontrol Anda. Kemudian Anda dapat mengonfigurasi pengontrol lebih lanjut.
For more details, refer to the Installation Guide of C5300.
Melalui Pengontrol Perangkat Lunak Omada Pro
Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.
Gambar 4-3
Kelola jaringan melalui Pengontrol Perangkat Lunak Omada Pro
Gerbang
Mengalihkan
Pengendali
Pengontrol Perangkat Lunak Omada Pro AP
AP
AP
berjalan di PC Host
Klien
Konfigurasi 29
Omada Campus Stackable L3 Managed Switch
1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web halaman. Jika tidak, klik Luncurkan Browser untuk Mengelola Jaringan.
2. Pada Pengontrol Omada Pro web halaman, ikuti panduan untuk menyelesaikan pengaturan cepat.
3. Setelah pengaturan cepat, halaman login akan muncul. Masukkan nama pengguna dan kata sandi yang telah Anda buat dan klik Masuk. Kemudian Anda dapat mengkonfigurasi pengontrol lebih lanjut.
4. Jika Anda ingin mengelola perangkat dari jarak jauh, ikuti langkah-langkah berikut:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web halaman, buka Setelan > Akses Cloud untuk mengaktifkan Akses Cloud dan mengikat ID TP-Link Anda. Jika Anda telah mengaturnya dalam pengaturan cepat, lewati langkah ini.
b. Luncurkan web browser dan masukkan https://omada.tplinkcloud.com di bilah alamat. Masukkan ID TP-Link dan kata sandi Anda untuk login. Daftar pengontrol yang telah terikat dengan ID TP-Link Anda akan muncul. Kemudian Anda dapat mengklik Luncurkan untuk mengonfigurasi pengontrol lebih lanjut.
Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.
Melalui Pengontrol Berbasis Cloud Omada Pro
Pengontrol Berbasis Cloud Omada Pro adalah alternatif yang baik tanpa perlu menginstal pengontrol perangkat lunak pada PC.
Lisensi perlu dibeli sebagai tambahan.
Gambar 4-4
Kelola jaringan melalui Pengontrol Berbasis Cloud Omada Pro
Awan Omada
Gerbang
Mengalihkan
AP
AP
AP
AP
Klien
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web peramban dan masukkan https://omada.tplinkcloud.com di bilah alamat. Masuk dengan
your TP-Link ID.
30 Konfigurasi
Omada Campus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
Anda dapat meluncurkan pengontrol untuk mengadopsi dan mengelola perangkat. * Aplikasi Omada Dengan aplikasi Omada, Anda juga dapat mengelola pengontrol di lokasi lokal atau lokasi jarak jauh melalui perangkat seluler Anda. Untuk konfigurasi detail, silakan lihat Panduan Pengguna pengontrol. Panduan ini dapat ditemukan di pusat unduhan situs web resmi kami. websitus: https://support.omadanetworks.com/product/.
Konfigurasi 31
Omada Campus Stackable L3 Managed Switch
Apendiks A Pemecahan Masalah
Q1. Apa yang bisa saya lakukan jika saya lupa nama pengguna dan kata sandi sakelar?
1. Hubungkan port konsol PC ke port konsol switch dan buka program emulasi terminal.
2. Matikan dan nyalakan kembali sakelar. Lakukan tindakan yang ditunjukkan oleh program emulasi terminal untuk mencapai menu bootUtil. Tindakan berbeda-beda pada setiap produk. Tindakan yang mungkin tercantum di bawah ini: · Tekan tombol apa saja untuk menghentikan boot otomatis. · Tekan CTRL-B untuk mencapai menu bootUtil.
3. Menu bootUtil akan ditampilkan. Masukkan angka 6 untuk memilih opsi "Pemulihan Kata Sandi" dan tekan Y untuk menghapus semua pengguna dan kata sandi. Kemudian, Anda dapat mengatur ulang nama pengguna dan kata sandi.
Q2. Mengapa LED PWR tidak berfungsi normal? LED PWR/Daya seharusnya menyala ketika sistem daya berfungsi normal. Jika LED PWR/Daya tidak berfungsi normal, lakukan langkah-langkah berikut:
1. Pastikan kabel daya terhubung dengan benar, dan kontak daya normal. 2. Pastikan voltage dari catu daya memenuhi persyaratan volume inputtage dari
mengalihkan.
Q3. Apa yang harus saya lakukan jika saya tidak dapat mengakses web halaman manajemen? Coba yang berikut ini:
1. Periksa setiap LED port pada switch dan pastikan kabel Ethernet tersambung dengan benar. 2. Coba port lain pada switch dan pastikan kabel Ethernet sesuai dan berfungsi normal. 3. Matikan switch dan, setelah beberapa saat, nyalakan lagi. 4. Pastikan alamat IP PC Anda diatur dalam subnet switch. 5. Jika Anda masih tidak dapat mengakses halaman konfigurasi, atur ulang switch ke default pabriknya. Kemudian
alamat IP PC Anda harus ditetapkan sebagai 192.168.0.x (“x” adalah angka dari 2 hingga 254) dan subnet mask sebagai 255.255.255.0.
Q4. Mengapa program emulasi terminal tidak ditampilkan dengan benar? Coba langkah-langkah berikut:
1. Pastikan catu daya normal dan kabel konsol tersambung dengan benar. 2. Periksa apakah kabel konsol berjenis benar. 3. Pastikan parameter program emulasi terminal sudah benar: konfigurasikan Bit per detik
sebagai 38400, Bit data sebagai 8, Paritas sebagai Tidak Ada, Bit henti sebagai 1, dan Kontrol aliran sebagai Tidak Ada.
32 Lampiran A Pemecahan Masalah
Omada Campus Stackable L3 Managed Switch
Lampiran B Spesifikasi
Specifications for S6500 Series Switches
Barang
Isi
IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x
Standar
IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)
IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)
10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)
S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54
Lampiran B Spesifikasi 33
Omada Campus Stackable L3 Managed Switch
Anggaran PoE
For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)
Suhu dan Ketinggian Operasional
For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters
Suhu Penyimpanan -40 °C hingga 70 °C (-40 °F hingga 158 °F)
Kelembapan Pengoperasian 10% hingga 90% RH Tanpa kondensasi
Kelembaban Penyimpanan
5% hingga 90% RH Non-kondensasi
34 Lampiran B Spesifikasi
Omada Campus Stackable L3 Managed Switch
Specifications for S7500 Series Switches
Barang
Isi
Standar
IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)
1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)
DIPIMPIN
Suhu dan Ketinggian Operasional
S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
Suhu Penyimpanan -40 °C hingga 70 °C (-40 °F hingga 158 °F)
Kelembapan Pengoperasian 10% hingga 90% RH Tanpa kondensasi
Kelembaban Penyimpanan
5% hingga 90% RH Non-kondensasi
For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
Ketinggian yang didukung adalah permukaan laut hingga 5000 m. Perlu dicatat bahwa jika ketinggian di atas 2000 m, setiap kenaikan ketinggian 220 meter, suhu operasi maksimum akan turun sebesar 1°C (1.8°F).
Lampiran B Spesifikasi 35
Omada Campus Stackable L3 Managed Switch
Spesifikasi Modul Catu Daya
PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)
PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)
Masukan Daya
100 V240 V~ 50/60 Hz 8A
100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see specifications for specific countries/ regions)
120 (not included)240V~ 50/60Hz 10A (for other locations)
100 V240 V~ 50/60 Hz 7A
Volume Keluarantage
Primary: 53.5 VDC Standby: 12 VDC
Primary: 53.5 VDC Standby: 12 VDC
Primary: 12 VDC Standby: 12 VDC
Arus Keluaran
9.35 A (Maksimum)
16.5 A (Maksimum)
45 A (Maksimum)
Daya Keluaran
500 W (Maksimum)
900 W (Maksimum)
550 W (Maksimum)
Ketinggian Operasional
For PSM500-AC/PSM900-AC: Sea level to 3000 m For PSM550-AC: Sea level to 5000 m
36 Lampiran B Spesifikasi
Peringatan Tanda CE
Ini adalah produk kelas A. Di lingkungan rumah tangga, produk ini dapat menyebabkan gangguan radio, sehingga pengguna mungkin diminta untuk mengambil tindakan yang memadai.
Deklarasi Kesesuaian UE
TP-Link dengan ini menyatakan bahwa peralihan ini telah memenuhi persyaratan penting dan ketentuan relevan lainnya dari arahan 2014/30/EU, 2014/35/EU, 2011/65/EU, dan (EU)2015/863. Deklarasi Kesesuaian UE asli dapat ditemukan di https://www.tp-link.com/en/support/ce/
Deklarasi Kesesuaian Inggris
TP-Link dengan ini menyatakan bahwa sakelar tersebut mematuhi persyaratan penting dan ketentuan relevan lainnya dari Peraturan Kompatibilitas Elektromagnetik 2016 dan Peraturan Peralatan Listrik (Keselamatan) 2016. Deklarasi Kesesuaian Inggris asli dapat ditemukan di https://www.tp-link.com/support/ukca/
Bahasa Indonesia:
PERINGATAN:
Sekring netral kutub ganda. Putuskan sambungan listrik sebelum melakukan servis.
Informasi Keselamatan
· Jauhkan perangkat dari air, api, kelembaban, atau lingkungan panas. · Jangan mencoba membongkar, memperbaiki, atau memodifikasi perangkat. Jika Anda memerlukan layanan, silakan hubungi kami. · Letakkan perangkat dengan permukaan bawahnya menghadap ke bawah. · Steker pada kabel catu daya digunakan sebagai perangkat pemutus, stopkontak harus
mudah diakses. · Hubungkan produk ke stopkontak dinding dengan koneksi pembumian melalui kabel catu daya
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
baterai.
· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.
Harap baca dan ikuti informasi keselamatan di atas saat mengoperasikan perangkat. Kami tidak dapat menjamin bahwa tidak akan terjadi kecelakaan atau kerusakan akibat penggunaan perangkat yang tidak tepat. Harap gunakan produk ini dengan hati-hati dan operasikan dengan risiko Anda sendiri.
Untuk dukungan teknis, panduan pengguna, dan informasi lainnya, kunjungi https://support.omadanetworks.com/, atau cukup pindai kode QR.