Spesifikasi
- Seri yang Didukung: KEYENCE KV-8000, KEYENCE KV-X310
- Weblokasi: http://www.keyence.com/
Petunjuk Instalasi
Pengaturan HMI:
| Parameter | Direkomendasikan | Pilihan | Catatan |
| Tipe PLC | KEYENCE KV-8000/KV-X (Symbolic) (Ethernet) | ||
| PLC I/F | Eternet | ||
| Pelabuhan no. | 8500 | ||
| Jenis perangkat | KV8000 | KV8000 / KVX | |
| Simulator daring | Ya | Koneksi multi-HMI | Ya |
Ekspor Tags:
Software KV STUDIO creates tag:
- Variable -> Cerected tag on Global or Local table.

- Support Sturcutre address.

- Ekspor tag: File -> Output CSV/TXT file -> Variable information

Impor Tags:
- In EasyBuilder Pro -> System Parameter Settings -> New Driver (KV-8000) -> Import Tags.

- Select the .txt file untuk mengimpor.

- Import some or all of the tags

- Pilih tag you want to import in Tag Manager, press OK.

- Impor tag informasi dengan sukses.

Jenis Perangkat Dukungan
| Tipe data | Format data EasyBuilder | Memo |
| BOLONG | sedikit | |
| KE DALAM | BCD 16-bit, Hex, Biner, Ditandatangani | 16-sedikit |
| UINT | BCD 16-bit, Hex, Biner, Tidak Bertanda Tangan | 16-sedikit |
| PENIPUAN | BCD 32-bit, Hex, Biner, Ditandatangani | 32-sedikit |
| UDINT | BCD 32-bit, Hex, Biner, Tidak Bertanda Tangan | 32-sedikit |
| NYATA | Mengapung 32-bit | 32-sedikit |
| NYATA | Mengapung 64-bit | 64-sedikit *Catatan 1 |
| RANGKAIAN | Deretan kata untuk input dan tampilan ASCII | *Catatan 2 |
|
Susunan |
BOOL, INT, UINT, DINT,UDINT, REAL,
LREAL, Structure *Catatan 3 |
|
|
Struktur |
BOOL, INT, UINT, DINT,UDINT, REAL, LREAL, STRING
Susunan |
- Catatan 1: EBPro V6.03.02 atau yang lebih baru mendukung tipe data 64 bit (hanya Seri cMT), tetapi harap perhatikan bahwa rentang batas alamat maksimumnya adalah 48 bit.
- Catatan 2: String In EasyBuilder Pro, only even addresses can be selected, and support string length up to 2000.

- Catatan 3: Support 1~3D array, 4D arrays and above cannot be imported.
Diagram Pengkabelan
Kabel Ethernet:

Tanya Jawab Umum
How do I connect multiple HMIs?
You can connect multiple HMIs using the on-line simulator option in the HMI settings.
What is the maximum string length supported for STRING data type?
In EasyBuilder Pro, only even addresses can be selected, and it supports string length up to 2000.
Dokumen / Sumber Daya
![]() |
WEINTEK KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller [Bahasa Indonesia:] Panduan Pengguna KEYENCE KV-8000-KV-X, KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller, Symbolic Ethernet Programmable Logic Controller, Ethernet Programmable Logic Controller, Programmable Logic Controller, Logic Controller |